Technical data Single valve
7.1.1.
Temperature class T6
max. permissible surface temperature for T6
Max. permis-
Temp.
sible ambient
Installation
class
temperature
[°C]
-40 ... +40
Block
installation
-40 ... +30
-40 ... +55
T6
-40 ... +50
Single
-40 ... +45
valve
-40 ... +40
-40 ... +35
85 °C
Ignition
Max. per-
Explo-
protec-
missible
sion
tion
output [W]
group
type
0,4
0,5
0,4
0,5
Ex ia
IIC
0,6
0,7
0,8
7.1.2.
Temperature class T5:
max. permissible surface temperature for T5
Max. permis-
Temp.
sible ambient
Installation
class
temperature
[°C]
-40 ... +55
-40 ... +45
Block
-40 ... +40
installation
-40 ... +35
-40 ... +25
-40 ... +70
T5
-40 ... +65
-40 ... +60
-40 ... +55
Single
valve
-40 ... +50
-40 ... +45
-40 ... +40
-40 ... +35
English
100 °C
Ignition
Max. per-
Explo-
protec-
missible
sion
tion
output [W]
group
type
0,4
0,5
0,6
0,7
0,8
0,4
0,5
Ex ia
IIC
0,6
0,7
0,8
0,9
1,0
1,1