12.

disasseMBly

12.1.
safety instructions
Danger!
risk of injury from high pressure!
Before dismounting lines and valves, turn off the pressure and
vent the lines.
risk of electric shock!
Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation!
Observe applicable accident prevention and safety regulations
for electrical equipment!
warning!
risk of injury from improper disassembly!
Disassembly may be carried out by authorized technicians only
and with the appropriate tools!
risk of injury from unintentional activation of the system and
an uncontrolled restart!
Secure system from unintentional activation.
Following disassembly, ensure a controlled restart.
30
english
Type 8690
Disassembly
12.2.
disassembly the pneumatic
control unit
procedure:
1. Pneumatic connection
Danger!
risk of injury from high pressure!
Before dismounting lines and valves, turn off the pressure and
vent the lines.
Loosen the pneumatic connection.
Series 20xx:
Loosen the pneumatic connection between Pneumatic Control
Unit and actuator.
2. Electrical connection
Danger!
risk of electric shock!
Before reaching into the system, switch off the power supply
and secure to prevent reactivation!
Observe applicable accident prevention and safety regulations
for electrical equipment!
Circular plug-in connector:
Loosen the circular connector.