Burkert 8690 Manuel D'utilisation page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. install sealing rings
Pilot air ports
Caution:
Collets must not be
fitted !
Fig. 8:
Installing of the sealing rings, 21xx series
Pull the form seal onto the actuator cover (smaller diameter
points upwards).
Check that the O-rings are correctly positioned in the control air
connections.
When the Pneumatic Control Unit is being installed, the collets
of the pilot air ports must not be fitted to the actuator.
14
Form seal
Installation of
the form seal
english
Type 8690
Installation
3. installation of the pneumatic Control unit:
Supports
Pilot air
ports
Fig. 9:
Installation of the Pneumatic Control Unit, 21xx series
Align the
Pneumatic Control Unit until the supports of the Pneu-
matic Control Unit can be inserted into the pilot air ports of the
actuator (see also "Fig. 9: ").
Push the
Pneumatic Control Unit, without turning it, onto the
actuator until no gap is visible on the form seal.
noTe!
too high torque when screwing in the fastening screw does
not ensure protection class ip65 / ip67!
The fastening screws may be tightened to a maximum torque of
0.5 Nm only.
Attach the Pneumatic Control Unit to the actuator using the two
side fastening screws. In doing so, tighten the screws only hand-
tight (max. torque: 0.5 Nm).
Fastening
screws
max. 0,5 Nm