2.3

Installing the gas/water supply/drain lines

D Supply and drain lines must not be in direct contact with heat sources (e.g. oven). The lines
must be installed with sufficient spacing to the heat source.
. Connect the water supply hoses to the installation module and ball valve/mixer tap and guide
to the installation compartment.
. Install the water drain hoses from the installation module/drain tap to the installation com­
partment with downward gradient.
. Install the gas supply lines from the gas installation module to the installation compartment.
Corrugated hose (with seal
Install the supplied seal
R 1/2 inch
Assambly instruction Cooking station
Specifications for assembly at the factory
on the union nut)
G 1/2 inch
R 1/2 inch
Corrugated hose, 1 m long:
- 750638 corrugated hose with braiding
DN12-1M, G ½ inch - R ½ inch, 1 m
Corrugated hose, 2 m long:
- 730327 corrugated hose with braiding
DN12-2M, G ½ inch - R ½ inch, 1 m
Gas lines
- do not bend
- do not crush
- protect against any harmful heat
- do not extend