Ingeteam

2. Unit description

2.1. Overview

The basic purpose of an inverter is to convert the direct current generated by the PV array into alternating current
to feed into the electricity grid.
The power structure of these inverters achieves a high performance with a flat curve, minimizing the cost and
weight of the inverter.
As standard the inverter includes communication via RS-485, an SD card reader for updating the firmware and
potential-free relay for signaling.

2.2. Optional accessories

These units may include the following accessories:
Communications accessories
Digital input card.
Self consumption kit.
Communication accessories
As standard these units have local communication via RS-485. In addition there is the option of establishing
connections using other technology types:
Ethernet (including communication via RS-485, for optional use).
Ethernet TCP (including communication via RS-485, for optional use).
GSM/GPRS (including communication via RS-485, for optional use).
Bluetooth.
Bluetooth (including communication via RS-485, for optional use).
Wi-Fi (including communication via RS-485, for optional use).
The instructions for installing the communications accessories are indicated throughout this manual. For more
information on their functioning, consult the corresponding communication accessories manual.
Digital input card
In certain countries this card is necessary to comply with their regulations.
Self consumption kit
These inverters are compatible with all the self consumption options offered by Ingeteam.

2.2.1. Overvoltage category (OVC)

These units comply with the standards IEC 62109-1 and IEC 62109-2.
These devices have been designed with an overvoltage category II (OVC II) on the DC side, and the alternating
current circuits with an overvoltage category III (OVC III).

2.3. Pollution degree

The units comply with pollution degree 3, as required for this type of inverter.

2.4. Acoustic contamination

The unit produces a slight buzz when in operation. Do not place it in an occupied room, or on light supports which
might amplify this buzz. The mounting surface must be firm and appropriate for the weight of the unit.