Maintenance
Clean the radiator fins and the cooling grids.
Perform a ventilation test to check that the fans turn (see section "10.22. Perform a ventilation test").
14.5. Replacing the fuses (INGECON SUN 3Play TL M)
TL M inverters are protected by a fuse for each string (both positive and negative poles).
The unit is delivered with fuses of 15 Adc 1000 V installed.
These fuses are available from Ingeteam as spare parts.
If you acquire the fuses from third parties they must meet the following specifications:
Maximum string power (Impp)
Gauge
15 A
12 A
10 A
8 A
6 A
To replace the fuses, proceed as indicated below:
1.
Remove voltage as explained in section "13. Shutting down the unit".
2.
Wait 5 minutes for the voltage to discharge.
3.
Open the unit.
4.
Check that there is no voltage on the unit.
5.
Remove the polycarbonate guard.
ABO2011IQM01_C - Installation and Operation Manual
DC fuses
4 ~ 4.5 A
4.5 ~ 6 A
6 ~7.5 A
7.5 ~ 9 A
9 ~ 11 A
Manufacturer
Bussmann
DF Electrics
Siba
Bussmann
DF Electrics
Siba
Bussmann
DF Electrics
Siba
Bussmann
DF Electrics
Siba
Bussmann
DF Electrics
Fuse gauge
6 A
8 A
10 A
12 A
15 A
Manufacturer reference
PV-15A10F
491629
50 215 28.15
PV-12A10F
491625
50 215 28.12
PV-10A10F
491620
50 215 28.10
PV-8A10F
491615
50 215 28.8
PV-6A10F
491610
Ingeteam