Troubleshooting
Minor Error Codes
Handset Error
Red LED
Code
Flashes
Ex1
2 Times
Ex2
2 Times
Ex3
3 Times
Ex4
4 Times
Ex5
5 Times
Ex6
6 Times
x - references a minor error code
Document Control
Original Instructions
Manual Reference: QTR-M002
Revision
-
Description
Over Current (Motor)
Over Current (Bat-
tery)
Under Voltage
Over Voltage
Over Temperature
Critical Low Voltage
Lockout
Description
Original Instructions
Possible cause and action
Usually caused by too heavy load on steep slope.
- Slowdown the speed or remove a bit of load
Usually caused by too heavy load on steep slope.
- Slowdown the speed or remove a bit of load
Usually caused by an flat battery
- Charge the battery or check the battery voltage
Usually caused by an incompatible battery or when
charger is in place while operation.
- Check battery type or unplug charger
Usually caused by prolong use on heavy load.
- Allow 5 minutes for electronics and motors to cool
down
- Break long operation (e .g. a long slope( into several
short journeys
Usually caused by loose or dry connections on the
wirings, occasionally caused by end of life battery.
- Check wiring and terminal conditions immediately
- Check battery health by proper equipment