3.1
GENERAL NOTES
RT and RP thermal cookers are endowed
with boiler to use the heating produced
by the device through a system with fluid
vector for heating and for the production
of hot water. The system must be designed
according to UNI 10412-2:2006 law by a
qualified thermal technician and must be
installed by experienced people according to
3.2
CONNECTIONS TO THE HEATING SYSTEM
RT Model 60-90-100 with flue
outlet on the right side
1 Connection detector of auxiliary thermostat (optional) Ø 1/2'' female
2 Going connection Ø 1''1/4 female
3 Bulb for thermal discharge detector (optional) Ø 1/2'' female
4 Connection for thermal discharge circuit (optional) Ø 1/2'' male
5 Return connection Ø 1''1/4 female
6 Connection discharge Ø 1/2 female
Picture 16 - Hydraulic connection scheme of a thermal cooker RT 60/90/100 with flue outlet on the right side (rear sight).
The thermal cooker with flue outlet on the left side is symmetrical.
RT 80 model with flue
outlet on the right side
1 Connection detector of auxiliary thermostat (optional)
Ø 1/2'' female
2 Going connection Ø 1''1/4 female
3 Bulb for thermal discharge detector (optional) Ø 1/2'' female
4 Connection for thermal discharge circuit (optional) Ø 1/2'' male
5 Return connection Ø 1''1/4 female
6 Connection discharge Ø 1/2 female
Picture 17 - Hydraulic connection scheme of a thermal cooker RT 80 with flue outlet on the right side (rear sight). The
thermal cooker with flue outlet on the left side is symmetrical.
3. HEATING SYSTEM
81
existing laws in particular to UNI 10683:2005
law. The thermal cookers are endowed with
all the necessary predispositions for a correct
installation, every external component (as
pumps, valves, acoustic alarms, pressure
switches) must be obtained by third parts
according to the specifies of designer and
installer.
6
5
6
5
800
4
2
3
1
4
747
684
634
256
127
92
600
4
3
2
1
4
747
684
634
256
127
42