Picture 9 - Flue outlet on the side. Fixed connector for the flue outlet on the side.
The connection with the chimney must be
always well fixed and sealed, it must not
have narrowing and must not decrease the
usable section of the chimney (see picture
6). If near the thermal cooker there is
Picture 10 - Installation with air intake in the room of installation and installation with air intake directly connected to the
wood fired thermal cooker
2.10
AIR OUTLETS
The standard installation of the wood
fired thermal cooker considers that the
comburent air is taken from the room where
the thermal cooker is installed through the
air intake of the thermal cooker located in
the plinth. In this case, in the room must be
always ensured the recycle of fresh air, in
particular if the room is small and window
and door frames are hermetic. The correct
flow of air in the room must be ensured
also in presence of other combustion based
devices, aspiring hoods, chimneys and vent-
inflammable material or high temperatures
sensible, the connection must be isolated
and the safety distances must be strictly
observed.
holes. The air intake in the room must have
a minimum surface of 80 cm
Rizzoli can give specific valves which can
allow the automatic opening of the air intake
only when it is necessary for the correct
working of the wood fired thermal cooker,
in order to warrant a maximum depression
of 3 Pa in the place of installation. RT and
RP range wood fired thermal cookers can
also be connected so that the comburent
air comes directly from outside. In this way,
for the wood fired thermal cooker it is not
77
. On demand,