Technical Data

kg
mm
40049470
500
820
40049471
1000
820
40049472
2000
820
40049473
3000
800
Noise emission - Sound level
The max. expected sound level [dB(A)] depends upon the driving power as
per diagram. The lifting table must be mounted in such a way that its noise
emission is not amplified.
In special design, the lifting table may be equipped with:
railing (for transportation of operating personnel)
underflow protection device
increase in base frame
overload sheet metal etc.
Mounting and taking into operation (see DIN EN ISO 13857 and EN 349)
The applicable regulations for buildings and safe operation must be observed during mounting.
Before mounting the lifting table, the necessary requirements on the operating site have to be fulfilled.
Prepare the mounting pits according to the enclosed mounting pit plan 6.8.9 sheet 28 and 29.
Reinforcement, concrete strength, and quality are to be determined by a construction expert.
Pay attention to exact dimensions and angles. Remove projecting ends of concrete or structural steel.
For outdoor assembly, a drainage with oil separator (acc. to local regulation) as per mounting pit plan has
to be provided.
In case of installation without mounting pit, safety measures that prevent injuries by squeeze or scissors areas
between basic frame and scissors are required (i.e. sheet steel covers).

Safety distances

The lifting table has to be located in such a way that squeeze- and scissors areas between mobile parts and
between mobile and fixed parts are avoided by keeping sufficient safety distance.
The safety distances are to be kept as follows:
for fingers
for toe
a = 25 mm
a = 50 mm
To avoid endangering the operator or any other person, other measures can be taken alternatively.
technische Änderungen vorbehalten
[mm/s]
[sec]
55
15
33
25
20
40
31
26
for hands
for arms and closed hands
a = 100 mm
design changes under reserve
[bar]
[bar]
[kW]
[l]
140
2,0
150
0,75
140
2,0
150
0,75
145
3,0
152
0,75
150
3,0
160
1,50
a = 120 mm
changements techniques sous réserve
F 06.08.151
[dB(A)]
 70
75
70
65
60
min dB(A)
max dB (A )
55
50
0
20
40
60
Lastanteil (%)
for feet
for the body
a = 120 mm
a = 500 mm
80
100
17