Hydraulic Lifting Table HTH-E SILVERLINE
English
Protective measure:
Connection, protective measures, and safety precautions have to be effected according to
local, national, and international regulations.
Before taking into operation, check:
correct polarity, turning direction, placement of order devices (with wrong polarity the motor will start, but no
lifting movement will be effected). Clamp correctly. Longer operation with a motor with wrong polarity may
damage the hydraulic aggregate.
protective conductor system
insulation resistance
overload protection adjustment (safety valve)
function
effect a test run
Position the lifting table and grout the foundation with concrete. When the concrete foundation is set,
make test runs with and without load.
Operation
An information sign "Operation of the lifting table only by authorised
persons" must be attached permanently at the control stations at a place
that is clearly visible.
The required direction is to be initiated by pressing the respective push-
button
In case of occurring faults, immediately stop operation and eliminate
the fault.
In case of danger, press the Emergency-stop
button.
Turn the button clockwise to start operation
again,
During operation, the operator always has to ob-
serve the load, the room below and above the
load and the load-carrying device.
For safety instructions refer to page 15.
When overload protection is effective, reduce the load.
There is a risk of overloading if the lifting table is loaded while extended.
The user must respond appropriately, e.g. weighing, to prevent overloading.
When leaving the control place, secure the lifting table against unauthorised operation (insert the padlock into
main switch and lock)
If the control place is left when the lifting table is extended, the maintenance supports have to be put in.
technische Änderungen vorbehalten
design changes under reserve
F 06.08.151