LIST OF ALARMS:
ALARM
Al.Heat.Exchange (16)
Al. Cylind.Probe (8)
Al. Evapor.Probe (11)
Al. IceHop.Probe (9)
Al.Hopper Probe. (7)
Al.Cond.Probe (18)
Al.Comp.Probe (46)
Mix Out
(
illuminated)
Safety Therm.Cyl (2)
Safety Therm.Hop (3)
Overload Beater (4)
Pressure Switch (5)
Overload Compres (6)
Wash today! (24)
Pasto needed! (25)
Spigot Opened (10)
Power On (13)
Ice Cylinder (14)
Timeout Prd. (15)
Why in STOP ?? (26)
Hopper Temp High 31
Barrel Temp High 32
During Pasteurisation:
TGV
(Bowl Evaporator output Temp.)
The machine only operates in Pasteurisation mode
Check that the transmission belt or the rotor is in the correct position.
Cylinder sensor failure. Critical alarm.
The machine goes into Stop from the Standby and Pasteurisation modes.
The Production mode can continue operating given that the consistency can be controlled.
Cylinder evaporator sensor failure.
The machine does not stop, in Pasteurisation mode the alarm is not visualised.
Bowl evaporator sensor failure. Critical alarm.
The machine goes into Stop from any mode.
Bowl sensor failure. Critical alarm.
The machine goes into Stop from any mode.
Condenser sensor failure. Critical alarm.
The machine goes into Stop from any mode.
Compressor sensor failure. Critical alarm.
The machine goes into Stop in any mode
Bowl empty. Fill bowl
The cylinder safety thermostat has come on. The machine goes into Stop
The bowl safety thermostat has come on. The machine goes into Stop
Bowl mixer motor overload. The machine goes into Stop
The pressure gauge has come on. The machine goes into Stop
Compressor motor overload. The machine goes into Stop
Obligatory Cleaning. See "washing and sanitisation" section
Obligatory Pasteurisation.
The machine has been in Stop for over 60 minutes with product in the deposit at a temperature of
15ºC or more.
Fit the tap to the machine
Signals that the machine's electricity supply has been interrupted.
Heat Exchange not suitable in the cylinder.
Problem with refrigeration in the cylinder, the product does not reach the suitable consistency while
it cools down. Check the mix load in the cylinder.
The machine warn that it is in Stop.
To confirm that we have put the machine in Stop, push the Stop button again.
Appears when the cylinder evaporator temperature reaches 85ºC. The machine goes into STOP. Only
the cleaning mode can be accessed.
Appears when the deposit evaporator temperature reaches 85ºC. The machine goes into STOP. Only
the cleaning mode can be accessed.
> TEV
(Bowl Evaporator Temp.)
EN_