H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
The working output power of the generator decreases by
about 10% per 1,000 m of altitude. During the welding pro-
cess no other device connected to the same generator should
Important
be operated.
3
Service and Repair
3.1
General
As the product is used in applications that are sensitive to safety con-
siderations, it may be serviced and repaired only by the manufacturer
or its duly authorized and trained partners. Thus, constantly high
standards of operation quality and safety are maintained.
Failure to comply with this provision will dispense the manu-
facturer from any warranty and liability claims for the product,
including any consequential damage.
When serviced, the unit is upgraded automatically to the technical
specifications of the product at the moment it is serviced, and we grant
a three-month functional warranty on the serviced unit.
We recommend having the product serviced at least every twelve
months.
3.2
Transport, Storage, Shipment
The product ships in a transport box. The product should be stored
in this box, protects the product from humidity and environmental
agents.
When sending the product, it should be placed into the transport box
at all times.
4
Principles of Operation
The HST 300 Manual USB 2.0 allows welding fittings that require
welding voltages from 8 V to 48 V. Every fitting has its own proper
welding voltage and welding time. To properly joint with the fitting,
these data have to be entered manually.
The microprocessor-controlled welding unit controls and monitors the
welding process in a fully automated fashion. A sensor at the welding
cable senses the outside temperature and adjusts the welding time
to it automatically
All data that are relevant for the joint or for traceability are saved to
the internal memory and can be sent to a USB stick.
The unit monitors the characteristics of its power supply continuously.
If one of these is out of tolerance, welding is aborted or cannot be
started.
5
Check-out and Operation
• To operate the welding unit, be sure that it is set on a proper,
level surface.
Version February 2014
HÜRNER HST 300 Manual USB 2.0 User's Manual
7
EN