Service And Repair; General; Transport, Storage, Shipment; Principles Of Operation - Hürner HST 300 aquatherm 2.0 Manuel Utilisateur

Masquer les pouces Voir aussi pour HST 300 aquatherm 2.0:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

a q u a t h e r m G m b H
Biggen 5
57439 Attendorn, Germany
3

Service and Repair

3.1

General

As the product is used in applications that are sensitive to safety con-
siderations, it may be serviced and repaired only by the manufacturer
or its duly authorized and trained partners. Thus, constantly high
standards of operation quality and safety are maintained.
Failure to comply with this provision will dispense the manu-
facturer from any warranty and liability claims for the product,
including any consequential damage.
When serviced, the unit is upgraded automatically to the technical
specifications of the product at the moment it is serviced, and we grant
a three-month functional warranty on the serviced unit.
We recommend having the product serviced at least every twelve
months.
3.2

Transport, Storage, Shipment

The product ships in a transport box. The product should be stored
in this box, protects the product from humidity and environmental
agents.
When sending the product, it should be placed into the transport box
at all times.
4

Principles of Operation

The HST 300 aquatherm 2.0 allows welding electrofusion fittings of
the supplier, aquatherm. The diameter of the fitting is selected manu-
ally. By entering the diameter, the operator provides the unit also with
the parameters it needs for properly welding that fitting.
The microprocessor-controlled HST 300 aquatherm 2.0 Welding Unit
• controls and monitors the welding process in a fully automated
fashion,
• determines welding duration depending on ambient tempera-
ture.
A temperature sensor located on the welding cable measures the
ambient temperature at regular intervals.
The output voltage at the welding cable is max. 48 volts transformed
by galvanic separation.
5

Check-out and Operation

• To operate the welding unit, be sure that it is set on a proper,
level surface.
• Be sure that power supply/generator protection is 16 A (slow
blow).
• Plug the power supply cord into the mains power supply or the
generator.
• Read and comply with the User's Manual of the generator, if ap-
plicable.
Version July 2014
HST 300 aquatherm 2.0 User's Manual
7
EN

Publicité

Table des Matières
loading

Table des Matières