Testing And Commissioning; Additional Documentation And Informations For The User - Ravelli MIA 90 Manuel De L'utilisateur

Masquer les pouces Voir aussi pour MIA 90:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Outlet height in the presence of a technical volume or obstacle with openings and windows
Outlet height in the presence of a technical volume or obstacle without openings

Testing and commissioning

Commissioning must be preceded by a test that involves the verification of the operation of the following elements:
- the suitability of the fumes exhaust system;
- connection to external air vents, if any;
- electric and hydraulic connections;
- check that all the materials that make up the smoke duct, flue, chimney terminal are suitable for use and compliant with standards
(fume exhaust of a stove with solid fuel).
For heat generating devices powered by mechanical systems testing must be done according to manufacturer's instructions.
The test is considered successfull when all operation phases are completed without encountering anomalies faults.

Additional documentation and informations for the user

Upon installation completion, the installer should hand over to the user:
- the user's manual of the appliance supplied by the manufacturer;
- the technical documentation of the accessories used and subject to maintenance;
- the documentation of the flue exhaust system;
-The system booklet (where applicable);
- the documentation that certifies installation completion;
The documentation required to cover installer's liability comprises:
- detailed description (including photos) of other heat generators present;
- declaration of conformity of the state-of-the-art system (D.M. 37/08);
- description of overall dimentions, layout or photos regarding the modifications brought to the layout in case it was necessary
to intervene during installation;
The use of certified material with CE marking (305/2011);
- any information regarding the warranty;
- the date and singature of installer;
User manual MIA 90
* If the terrace or flat roof is walkable, you should observe the relative distanc-
es from the floor recommended for roof with slope β ≤ 10°.
The symbol Z indicates the height (mm) from
the obstacle or the technical compartment
Roof with slope β ≤ 10°
Distance
Outlet height
(mm)
X ≤ 2000
Z + A
2
X > 2000
B
The symbol Z indicates the height (mm) from the obstacle or the technical
compartment.
Vers. 1 du 20/10/16
Page106
Roof with slope β > 10°
Distance
Outlet height
(mm)
X ≤ 3000
Z + A
2
X > 3000
B
EN