Alarms (Table With Reference Codes) - Ravelli MIA 90 Manuel De L'utilisateur

Masquer les pouces Voir aussi pour MIA 90:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Alarms (table with reference codes)

TITLE
CODE
AL 01
BLACK OUT
FLAME
TEMPERATURE
AL 02
FAULTY
AL 03
FLAME OVERTEMPERATURE
AL 04
FUME EXHAUST DAMAGED
AL 05
NO SWITCH-ON
AL 06
PELLETS FINISHED
RESET CIRCUIT BREAKER / DOOR
AL 07
OR ASH PAN OPEN
AL 08
DEPRESSURIZATION
AL 12
FUME EXHAUST SYSTEM FAILURE
AL 14
SCREW PHASE
AL 15
SCREW TRIAC
AL 19
CLEANER FAILURE
User manual MIA 90
REASON
- No voltage during work phase
- The flame probe is malfunctioning
PROBE
- The fume probe is disconnected from the electronic
board
-The temperature of the flame is too high
- Fume extractor encoder is not working or is
connected incorrectly
- No power to fume extractor.
- The fume extractor is blocked
- The pellet hopper is empty.
- Pellet calibration and suction during ignition phase
is incorrect.
- The ignition coil is faulty or positioned
incorrectly
- The pellet hopper is empty.
- The gear motor is not loading pellets
- Not enough pellets loaded
- The manual reset thermostat connected to the
hopper
was triggered
(RESET CIRCUIT BREAKER) /
Door, ash pan or pellet door open
- Combustion in the brazier is not optimal due to
clogging or obstructions of internal stove ducts
inside of the cooker.
- The flue is blocked.
- The vacuum meter is faulty.
- The fume exhaust system has a loss of performance
due to
fan obstruction or
voltage drop.
- No cable connection to power the gear motor
of the auger
- An internal part of the electronic board that controls
the pellet infeed screw is faulty.
pellet
- Possible voltage drops or incorrect input voltage
cooker input
- The cleaner did not complete the movement
and is not in the correct position or the
fire door is not closed properly.
(RESET CIRCUIT BREAKER)
Page133
SOLUTION
- Press the switch off key and switch on
cooker switch-on
- If the problem persists, contact the
Support Service.
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Check for the presence of pellets in the
container.
Top up, if necessary.
- Contact the Support Service
- Contact the Support Service
- Check for the presence of pellets in the
container.
Top up, if necessary
- Empty the tank to see if there are any
objects inside that may prevent
the proper operation of the auger.
of the auger.
- Regulate pellets setting from "SET AIR/PELLETS"
- If the problem persists, contact the
Support Service
- Reset the thermostat by pressing the appropriate
button
or close the
doors.
- Switch off the cooker, clean the brazier, operate
tube bundle and adjust the
combustion setting the Pellet/Air values
- Contact the Support Service
- Check the flue is free and
clean.
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Check the mains voltage.
-Check if the door is closed
properly and Reset the alarm and
wait until the cooker goes to the state
OFF. Cut power off and then power on, the
system reactivates the cleaner trying to
search the correct position again.
- If the problem persists, contact the Support
Service
Technical
Vers. 1 du 20/10/16
EN

Publicité

Table des Matières
loading