6.2
Assembly of refractory bricks
The base made in refractory material supplied already assembled, should be reviewed to verify if during transport the
components of the base have moved by creating an incorrect levelling which would not make it possible to proceed to the
assembly of the remaining refractory bricks.
To restore the levelling of the bases, shim where necessary the lateral and central bases using the supplied adhesive glass
fibre (Fig. 6.2a).
Insert the two side refractory bricks inside the combustion chamber, delivered separate from the appliance, inserting them
in the appropriate guides (Fig. 6.2b).
Fig. 6.2b
Fig. 6.2a
Product images are purely indicative
36
cod. 004777520 - 21/03/2019 - Palazzetti - PN - Italy