Installation instructions, only for experts
2. Pull the two half-shells of the bench sensor apart.
3. Connect the two connectors for the bench sensor wire to the two middle
terminals on the connection panel.
4. Place the connection panel crossways in the bench sensor half-shells.
5. Place the two half-shells together and screw them together using the two
cross-head screws (9 mm).
6. Check whether the bench sensor has been securely closed.
7. Install the bench sensor on the wall of the sauna room using the two
wood screws enclosed (16 mm). Maintain a gap of 15 cm to the roof of the
sauna room.

4.5. Installing the foil sensor (optional)

If one of the following infrared heat plates is connected to an additional output,
the foil sensor P-ISX-FF must be used:
● IR-WP-100
● IR-WP-175
● IR-WP-390
● IR-WP-510
● When installing the foil sensor, observe the operating instructions for the
infrared heat plates.
● The foil sensor must be activated when starting up the sauna for the first time
(see 8.5. Activating/deactivating the foil sensor on page 26).
● IR-WPHL-100
● IR-WPHL-175
● IR-WPHL-390
● IR-WPHL-510