Activating Single-Sensor Mode; Activating/Deactivating Phase Alignment; Setting The Light Operating Mode - Harvia SENTIO Just Sauna Fin Instructions D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 82
Installation instructions, only for experts

8.2. Activating single-sensor mode

In single-sensor mode, the sauna control unit is operated with the heater sensor
with an excess temperature fuse (F1) only. The single-sensor mode must be
activated above the function selection switch 2.
● The function selection switch 2 is set to the ON position as standard. This ac-
tivates two-sensor mode.
● If you wish to deactivate single-sensor mode, place the function selection
switch 2 in the OFF position.

8.3. Activating/deactivating phase alignment

Phase alignment is activated or deactivated using the function selection switch 3.
● The function selection switch 3 is set to the ON position as standard. This ac-
tivates phase alignment.
● If you wish to deactivate phase alignment, place the function selection switch 3
in the OFF position.

8.4. Setting the light operating mode

The light for the sauna room can either be dimmed or switched on and off.
The dimmer switch function is activated or deactivated using the function selec-
tion switch 5.
● The function selection switch 5 is set to the ON position as standard. This ac-
tivates the dimmer function.
● If you wish to deactivate the dimmer function for the sauna room light, place
the function selection switch 5 in the OFF position.
p. 25/40
EN

Publicité

Table des Matières
loading