Problem
Dust escapes from
the device during
cleaning.
The battery is not
charging up. The
charge control
lamp (19) is off.
Unusual odour
Technical Data
Article number:
Device
Model number:
Voltage supply:
Motor power:
Battery charge time:
Battery operating time:
Capacity of collecting
container:
Protection class:
Type of protection:
Mains adapter
Model number:
Voltage supply:
Output:
Protection class:
29
Possible cause / solution
•
Check whether the collecting container (5), fi lter protection 6)
and HEPA fi lter (7) have been inserted correctly and adjust
the fi t if necessary.
•
Is the HEPA fi lter (7) worn or damaged? Order a new HEPA
fi lter (7) via www.service-shopping.de and replace it.
•
Both ON / OFF switches (11, 17) must be in the OFF position
for the battery to be able to charge.
•
Is the device seated correctly in the frame (24)?
•
Is the mains adapter (1) plugged correctly into the plug
socket and is the barrel connector plugged correctly into the
charging socket (20)?
•
Is the plug socket defective? Try another plug socket.
•
Check the fuse of the mains connection.
•
A new odour is normal when the device is used for the fi rst
time; it disappears after a while.
06260
NK-165
9.6 V DC, 2000 mAh (Ni-MH battery)
70 W
approx. 12 hours; 12 – 15 hours for the fi rst charge
approx. 16 – 20 minutes (with fully charged battery)
approx. 500 ml of dust, approx. 150 ml of liquid
III
IPX4 (protection against splashing from all directions)
FD35VD-12-200
230 – 240 V ~ 50 Hz, 40 mA
12 V DC, 200 mA
II