Proper cleaning, maintenance and the use of clean, dry, quality fuel will prevent common operational problems. When your Pit
Boss
grill is operating poorly, or on a less frequent basis, the following troubleshooting tips may be helpful.
®
For FAQ, please visit www.pitboss-grills.com . You may also contact your local Pit Boss
Service for assistance.
WARNING: Always disconnect the electrical cord prior to opening the grill for any inspection, cleaning,
maintenance or service work. Ensure the grill is completely cooled to avoid injury.
ELECTRIC SMOKER
SYMPTOM
No Power to controller
Power light/ Heating light not on
Element not on
Cabinet Temp is inaccurate
Appliance takes excessive amount
of time to heat
Gap between the door & smoker
No smoke
Controller will not adjust temp
TROUBLESHOOTING
CAUSE
Not plugged into outlet
House breaker or GFI tripped
Bad connection at controller
Faulty Controller
Appliance not powered on
Faulty controller
Bad connection at the element
Faulty element
Faulty Temp Sensor
Faulty controller
Climate
Appliance plugged into an extension cord Plug appliance directly into power source. Maximum
Door not closed properly
Faulty controller
Door alignment
Damaged door seal
No wood chips
Element not staying on long enough to
heat chips due to TEMP set too low
Damaged wood chip box
Faulty controller
authorized dealer or contact Customer
®
SOLUTION
Plug in to power source
Reset breaker or GFI. Min. 15 amp
Unplug connection and reconnect.
Call for replacement.
Turn on the Controller
Call for replacement.
Unplug connection and reconnect.
Call for replacement.
Clean temperature probe using a soft cloth.
Call for replacement.
Call for replacement.
Temps below 65°F (18°C) may extend heating time
Length extension cord 25 ft, min. gauge 12/3.
Close door and adjust latch so door seals completely
Adjust door hinges
Call for replacement door kit
Close door and adjust latch so door seals, completely
around appliance.
Move appliance to level surface and adjust height
Open vent fully.
Re-set TEMP higher to turn on the element.
Call for replacement.