ELGA-TB-G/-RF(-F1)
5.1.3
Installing the external accessories
To protect the end positions against uncontrolled overtravel:
Check whether proximity sensors are necessary (hardware limit switches).
If proximity sensors are used as limit switches:
Preferably use proximity sensors with normally-closed function.
These will protect an ELGA against overtravel of the end position in case of a broken proximity
sensor cable.
If proximity sensors are used as reference switches:
Use proximity sensors that correspond to the input of the controller being used.
Use proximity sensors with switch lug aC (è Mounting instructions of the accessory used).
Mounting
in the slots 9 (è Fig. 2)
1) For ELGA-TB-RF-F1 no slots available
2) Only for ELGA-TB-RF-F1
Tab. 4
Avoid external influences from magnetic or ferritic parts in the vicinity of the proximity sensors (min
imum distance of 10 mm from the slot nuts).
To avoid contamination:
Use slot covers in all unused slots.
Festo – ELGA-TB-G/-RF(-F1) – 1409b English
with sensor bracket aD
1)
aC
9
with mounting kit aE
aD
aC
2)
aC
aE