IMPORTANT REMARkS
READ THE FOLLOWING REMARkS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLA-
TION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARkED WITH THE SYMBOL
NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORk-
ING ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM.
• Theseinstructionsareaimedatprofessionallyqualified"installers of electrical
equipment" and must respect the local standards and regulations in force.
All materials used must be approved and must suit the environment in which
the installation is situated.
• All maintenance operations must be carried out by professionally qualified
technicians. Before carrying out any cleaning or maintenance operations
make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has
been made. "i.e. for the automation of hinged gates" with one or two gate
leaves, max. length 2 m, max. weight 150 kg.
• The unit may be fitted both to the right and to the left of the passageway. This
product and all its relative components has been designed and manufactured
by Cardin Elettronica who have verified that the product conforms in every
aspect to the safety standards in force.
Any non authorised modifications are to be considered improper dangerous
and the complete responsibility of the installer.
IMPORTANT! The geared motor is not fitted with a torque limiter.
Only use an electronic programmer which has a torque limiter with
maximum force at the head of the gate equal to 150 N.
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public
safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the
main road to eliminate possible traffic disruptions.
2) The operator must be installed on the inside of the property and not on the
public side of the gate. The gates must not swing outwards onto a public area.
3) The gate operator is designed for use on gates through which vehicles are
passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls must be
situated in a position where the operator can see the gate at all times.
5) At least two warning signs (similar to the example on the right) should be
placed, where they can be easily seen by the public, in the
area of the system of automatic operation. One inside the
property and one on the public side of the installation.
These signs must be indelible and not hidden by any
objects (such as tree branches, decorative fencing
etc.).
6) Make sure that the end-user is aware that children and/
or pets must not be allowed to play within the area of a
gate installation. If possible include this in the warning signs.
7) Whenever a fully open gate leaf comes within at least 500 mm of a fixed
structure the space must be protected by an anticrush buffer (fig. 1, detail 11).
8) A correct earth connection is fundamental in order to guarantee the electri-
cal safety of the machine
9) If you have any questions about the safety of the gate operating system,
do not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
- 24 Vdc motor.
- Carter in shock-proof plastic.
- Release mechanism components in shockproof plastic.
- Geared motor with steel gears enclosed in a die cast two-piece aluminium
shell.
- The geared motor is fitted with two micro switches; one for closing "FCC"
and one for opening "FCA" (see wiring diagram).
- Motor support base in zinc-plated steel
- Articulated operator arm in die cast aluminium
- Lubrication using permanently fluid grease.
ACCESSORIES
980/xLSE11C - Electric lock 12 Vac.
IMPORTANT REMARkS
USER INSTRUCTIONS
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user
is therefore obliged to either take the product to a suitable dif-
ferential collection site for electronic and electrical goods or to
send it back to the manufacturer if the intention is to replace it
with a new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials. Illicitly disposing of this
product by the owner is punishable by law and will be dealt with according
to the laws and standards of the individual member nation.
During the opening/closing manoeuvre check for correct operation and
activate the emergency stop button in case of danger.
During blackouts the gate can be released and manually manoeuvred using
the supplied release key (see manual release pag. 7).
Periodically check the moving parts for wear and tear and grease if required
using lubricants which maintain their friction levels unaltered throughout
time and are suitable for temperatures of -20 to +70°C.
In case of failure or operational anomalies switch off the power at the mains
do not attempt to repair the appliance yourself.
Periodically check the correct operation of all safety devices (photoelectric
cells etc.). Eventual repair work must be carried out by specialised person-
nel using original spare parts. The appliance is not suitable for continuous
operation and must be adjusted according to the model (see technical
data on page 20).
INSTALLATION INSTRUCTIONS
The minimum controls which may be installed are OPEN-STOP-CLOSE,
these controls must be installed in a location not accessible to children
and outside the opening range of the gate.
Before starting the installation of the system check that the structure
WARNING
which is to be automated is in good working order and respects the local
AUTOMATIC OPENING
standards and regulations in force.
kEEP CLEAR
To this end make sure that the gate is sufficiently rigid (if necessary rein-
force the structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which
maintain unaltered friction characteristics over a period of time and are
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
suitable for temperatures of -20 to +70°C.
NEAR THE INSTALLATION
• Check the safety measures between the fixed and moving parts:
- a minimum space of 30 mm must always be left along the entire dis-
tance between the gate and the support column measured throughout
the entire opening angle of the gate.
- make sure that the space between the bottom of the gate and the
pavement never exceeds 30 mm throughout the entire opening angle
of the gate.
• The surface of the gate must not feature openings which allow a person's
hand or foot to pass through.
• Check the exact positioning of the pivots, and their good working order
(the upper and lower hinges/pivots must be aligned on the same axis).
• Work out the run of the cables according to the command and control
devices fitted and make sure the system conforms to the local standard
and regulations in force (see installation example fig. 1 pag. 2).
• Check that the appliance is suitable for the size, weight and duty cycle
of the gate to which it is to be applied (see duty cycle on page 20)
FITTING THE UNIT
The unit may be positioned either to the right or to the left of the pas-
sageway:
- if you have acquired a kit for 2 gate leaves the geared motors are
factory set for left and right installation (see the adhesives "Sx" left
and "Dx" right on the motors);
11
IMPORTANT REMARkS