Wiring
To allow for ease of wiring, the enclosure wiring
area is free of electronics other than the terminals.
Conduit holes and knockouts are located so
that the wire can be fed straight through to the
connectors, with minimal bending. The terminals
accept 6-14 AWG wire.
Installations that require larger wire gauge than
6 AWG will require an external junction box. Run
6 AWG wire from the Drive into the junction box,
then make external connections with wire nuts to
appropriately sized wire.
NOTICE For convenience in wiring, the input and
motor terminals unplug from the box. Pull them
down to remove them for ease of access, as shown
in Figure 8.
Verify that the terminal connectors are completely
seated when you replace them. It is best practice
Figure 8 - Pull input and motor terminals down to
remove, making wiring easier.
01+ 01+
Terminal
Removable
(pull down)
Input Power
Connections
Ground Screws
Figure 9 - Basic Wiring Connections for Startup
5999 0509
I1+ I1-
I2+ I2-
Green Cable Shield/Screw
Input
Green/Yellow
(Ground)
to connect all output wires (larger wire gauge) first,
then all input wires.
Pump Connections
If the PENTEK INTELLIDRIVE is used with above
ground motors not rated for Variable Frequency
Drive use, maximize motor life by limiting lead
length to 25 ft. Refer to the pump owner's manual,
the National Electrical Code, and local codes for
proper wire size.
The output of the Drive is single phase (2-wire or
3-wire) or 3-phase, depending on motor selection
during startup.
The output power terminals (motor wire
connections) are located on the lower right side
of the Drive and are labeled R (Red), Y (Yellow),
and B (Black). See Tables 2 through 6 for suggested
wire sizes.
Feed the motor cable through the 3/4" conduit hole
on the bottom right side and into the appropriate
terminals. If the wire is large enough to require a
larger conduit hole, remove the 1-1/4" knockout
and use the appropriate conduit connections.
Attach the motor ground wire to the grounding
screw, located to the upper right of the terminal
block. Attach the motor power wires to the
terminals as shown in Figure 9.
NOTICE Drive does not sense motor temperature
and will not protect motor from over heating.
V+
V-
AI+ AI-
P
Red to AI+
Black to AI–
Transducer Cable
Connections
N
SD CARD
Terminal
Removable
(pull down)
Red
Yellow
Black
Motor Connections
Output
Ground Screw
Green/Yellow (Ground)
Submersible Motor: 3-Ph./ 3-W. 1-Ph., follow colors as above.
Submersible Motor: 1-Ph./ 2-W., connect to Y and B, any order.
Above-Ground Motors: L1 to R, L2 to Y, L3 to B; verify rotation.