Initial Start-up
3. Pump out well (if necessary):
Direct pump's discharge to appropriate location
not connected to system and press Pump Out.
The pump will run at 45 Hz.
Adjust frequency as appropriate:
A. Press ENTER
B. Change frequency value
Table 8 - Pentek Motor Service Factor Amps
Motor
PENTEK Part
Type
Number
P42B0005A2-01
P42B0007A2-01
P42B0010A2-01
P42B0015A2-01
2-Wire
P42B0005A2
P42B0007A2
P42B0010A2
P42B0015A2
P43B0005A2-01
P43B0007A2-01
P43B0010A2-01
P43B0015A2-01
CS/CR
P43B0005A2
3-Wire
P43B0007A2
P43B0010A2
P43B0015A2
P43B0020A2
P43B0005A3
P43B0007A3
P43B0010A3
3-Phase
P43B0015A3
P43B0020A3
P43B0030A3
P43B0050A3
NOTICE Above ground pumps should run at 60
Hz for this step (until pump is primed). Then
adjust frequency as necessary.
C. Press ENTER again.
Run the Drive in this mode until the well
discharge runs clear, then press STOP button to
stop Drive.
Risk of explosion. In Pump Out
mode, pump runs at a constant speed, which
can cause very high pressure if flow is restricted.
Rating @
Service
230V
Factor
Amps
HP
1/2
4.7
3/4
6.2
1
8.1
1-1/2
10.4
1/2
4.7
3/4
6.4
1
9.1
1-1/2
11.0
1/2
4.8
3/4
6.0
1
7.3
1-1/2
10.9
1/2
4.9
3/4
6.3
1
7.2
1-1/2
11.1
2
12.2
1/2
2.9
3/4
3.9
1
4.7
1-1/2
6.1
2
7.6
3
10.1
5
17.5
4. Verify installation: Make sure that the system has
properly-sized, pressure-relief valve and pressure
tank.
Make sure pressure tank's precharge is correct.
See Table 7.
Make sure pump discharge is connected to
system.
5. System Start:
A. Open valves at the ends of lines so that air
will escape during pressurization.
B. Press Auto Start; close valves at the ends of
lines after all air has escaped.
C. The system goes into Constant Pressure
Operation as soon as the transducer registers
the Dry Run Sensitivity parameter (default
is 10 PSI). If system pressure does not reach
that PSI value within 3 minutes, the Drive will
stop. Press Auto Start again to restart line fill.
If longer priming or line fill time is required,
adjust Fill Time parameter. See Table 9.
Changing a Parameter Value
This procedure works for ANY parameter.
A. Press MAIN MENU button.
B. Follow the keypress sequence shown in
Figure 12:
A shorthand way to remember this is:
• Press ENTER to change a value
• Press ENTER again to save it
• If new value is not saved, any screen change will
result in the loss of the new value.
Use arrows to
find parameter
Press Enter
to change value
Figure 12 - Changing parameter value.
Table 9 lists all available commands and
parameters for the PENTEK INTELLIDRIVE.
Use arrows
Press Enter
to save
6567 0512
12
12