Specifications/Ratings
Input Voltage ........... 1-Phase 230VAC Nominal (190–265VAC)
Input Frequency ......................................................... 50/60Hz
Ambient Temperate Range ............ -4 to 122 °F (-20° to 50 °C)
Output Connections ..................3-Phase, 3-Wire/1-Phase or
Max Motor Cable Length .......................................... 1,000 feet
Enclosure ..............................................................................3R
Table 1 - Specifications
Max
Input
Model
HP
Phase
PID10
1.0
PID20
2.0
PID50
5.0
The PENTEK INTELLIDRIVE is specifically designed
to operate 4" submersible pumps and 3-phase
above ground pumps in water well and residential
booster applications. Each Drive is rated for
maximum output amp rating. Any use of Drive
outside of intended design parameters will void
warranty. If Drive is used with above ground motors
not rated for a Variable Frequency Drive, maximize
motor life by limiting lead length to 25 ft. Refer to
pump Owner's Manual and the National Electrical
Code for proper wire size.
Gnd
(3 phase only)
Figure 1 - A typical residential installation layout
1-Phase/2-Wire
Motor
Operation
2-wire, 3-wire,
1
3-phase
2-wire, 3-wire,
1
3-phase
PENTEK
INTELLIDRIVE™
Gnd
Each carton contains:
PENTEK INTELLIDRIVE
• Pressure Transducer
• 10' Pressure Transducer Cable
• Quick Start Guide
• Owner's Manual
PENTEK INTELLIDRIVE Model Number Structure
Max
PIDXX
Amps
10.5
Product Family
13.5
PID - PENTEK INTELLIDRIVE
18.0
HP Range
10 = up to 1.0 HP
20 = up to 2.0 HP
50 = up to 5.0 HP
The PID10 and PID20 will operate a 1-phase 2-wire,
1-phase 3-wire, and 3-phase motor up to the HP
range of the Drive. The PID50 will operate 1-phase,
2-wire and 3-wire up to 2 HP and a 3-phase motor
up to 5 HP.
Variable Frequency Drive
Transducer; install in straight
pipe downstream of tank, at
least one foot away from
pipe fittings on each side.