Requirement: The appliance is ready for
operation.
Press the "Service" button as
1.
well as the "Coffee" direct key for more
than 2 seconds to enter Service
mode 2.
Press the "Service" button
2.
repeatedly until the display for the
Venting function appears.
Press the "Service" button for
3.
more than 2 seconds to start venting.
The Ready display flashes until
»
venting is ready to start.
The Water display lights up and
»
requests you to remove the water
tank.
4. Remove the water tank and empty it.
The Steam display lights up and
»
requests you to open the "valve".
5.
Open the "valve".
»
Water and steam escape from the
Cappuccinatore.
The Steam display flashes.
»
»
The Steam display lights up and
requests you to close the "valve".
6.
Close the "valve".
»
The appliance is vented and switches
off automatically.
8.2 Transporting the
appliance
ATTENTION
Freezing residual water can damage the
appliance.
Prevent the appliance from being
exposed to temperatures below 0 °C.
Transport the appliance in the original
packaging. This avoids damage in transit.
Before transporting the appliance, carry
out the following activities:
1. Vent the appliance (see section 8.1
Venting the appliance on page 54).
2. Empty the drip tray and the coffee
grounds container.
3. Empty the water tank.
4. Empty the bean container.
5. Clean the appliance (see section 7.1
General cleaning on page 48).
6. Package the appliance.
Information
ū When sending the appliance to Melit-
ta's service centres, it is not necessary
to send in the cup plate. This prevents
scratches during transport.
ū Do not use commercially available
adhesive and packing tapes to attach
loose parts. When detached, adhesive
residues remain on the appliance
which are difficult to remove.
8.3 Disposing of the
appliance
Appliances marked with this symbol
are subject to European Directive
2002 / 96 / EC for WEEE (Waste Electri-
cal and Electronic Equipment).
Electrical appliances do not belong in
domestic waste.
Dispose of the appliance in an environ-
mentally friendly manner via suitable
collection systems.
9
Technical data
Technical data
Operating voltage
Power consumption
Pump pressure
Dimensions
Width
Depth
Height
Technical data
220 V – 240 V, 50 Hz – 60 Hz
1450 W
max. 15 bar
200 mm
460 mm
353 mm
55