Maintenance; Replacing The Oil; Cleanliness; Replacement Parts - SKF 729124 Mode D'emploi

Masquer les pouces Voir aussi pour 729124:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10

4. Maintenance

4.1 Replacing the oil

When replacing the oil or after maintenance, make sure no air is trapped in the system.
This should be checked before attaching the hose to the application by making sure only
air-free oil comes out of the hose when pumping. Only use clean, recommended hydraulic
oils.

4.2 Cleanliness

Keep the pump clean from dirt and metal particles in order to avoid excessive wear.

4.3 Replacement parts

Designation
Description
729108
Gauge nipple
729124-1
Hand-pump (sub-assembly)
729124-3
Repair kit
729124-4
Release knob and spindle
729124-5
Oil container tube
729831 A
Quick connection coupling, G
729832 A
Quick connection nipple, G
729126
High pressure hose
1077587/2
Pressure gauge (100 MPa, 63 mm)
THGD 100
Digital oil pressure gauge*
Items marked* are ONLY for 729124 DU.
4.4 Accessories
Designation
Description
LHMF 300/5
Mounting fluid (5 litre, 300 mm
LHDF 900/5
Dismounting fluid (5 litre, 900 mm
SKF 729124
/
1
4
/
1
4
/s at 20 °C)
2
/s at 20 °C)
2
7

Publicité

Table des Matières
loading

Table des Matières