C
L
A
C
N
A
E
L
C
4219-450-08051 MANUAL GAG. CAD. MILK EN-FR 120US.indd 31
5
Empty the entire bottle of Gaggia descaling solution into the water tank and fill
the tank with water up to the CALC CLEAN notch. Reinsert it in the machine.
6
Place a large container (1.5l) under the steam tube and the coffee spout.
7
Follow the instructions shown on the display to launch the descaling
procedure. This procedure lasts approximately 25 minutes and consists of
a descaling cycle and a rinse cycle, carried out with dispensing at regular
intervals.
8
Once the descaling cycle is complete, rinse the water tank, and water circuit,
following the instructions shown on the display.
9
Replace the INTENZA+ filter into the water tank.
Note: it is possible to pause and resume the procedure at any time by pressing the
START/STOP
button.
START/STOP
Warning: when the descaling procedure is active, the brew group cannot be
removed. Wait for the descaling process to end, then remove the brew group.
What to do if the descaling process is interrupted
You can exit the descaling procedure by pressing the ON/OFF
control panel. If the descaling procedure is interrupted before its completion,
proceed as follows:
1
Empty the water tank and wash it thoroughly.
2
Fill the water tank with fresh water up to the CALC CLEAN notch and switch
the machine on again. The machine will warm up and perform an automatic
rinse cycle.
3
Before preparing any beverage, perform a rinsing cycle as described in the
specific chapter.
Note: if the procedure has not been completed, it will be necessary to carry out
another descaling procedure as soon as possible.
English
31
button on the
ON/OFF
23/04/2020 09:58:05