use of the wood and a soot deposits in the chimney.
Dimensional drawing
The illustration indicates the approximate center
height of the hole for the flue. Distortions in floors
and walls may influence the height. Place the stove
for accurate position and height of the flue/chimney
connection. We accept no liability for typographical
errors and changes.
For your own safety, comply with the assembly instructions.
All safety distances are minimum distances. Installation
of the stove must comply with the current rules and
regulations of the country where the product is installed.
Nordpeis AS is not responsible for wrongly assembled
stoves.
Subject to errors and changes.
For the latest updated version go to www.nordpeis.com.
2. Technical Information
This is a clean burning stove, which has a minimal
emission of soot particles and un-burnt gases (e.g.
CO). Use exclusively clean and dry wood.
Stove:
Material:
Surface treatment
door/doorframe:
Fuel:
Operating range:
Draught system:
Combustion system:
Heating area:
Flue outlet:
Flue:
Weight of stove:
Flue gas temperature 287 °C
Air supply
requirements (m³/h):
Fuel charge
Refueling interval
Opening of the air
vent control
Operation
* Intermittent combustion refers to normal use of a fireplace,
i.e. new wood is inserted when the previous load has burned
down to ember.
Casa
Cast iron / sheet steel
Varnish
Wood logs, 30 cm
3-7 kW
Air vent control
Secondary combustion
(clean burning)
Until 100 m²
Top and posterior
Outer Ø 150 mm
121 kg
10
1,1kg
45 min
100%
Intermittent*
3. Distance to combustible material
(FIG 1) Ensure that the safety distances are
respected.
When connecting a steel chimney to the top outlet use
the security distances required from the manufacturer.
4. Assembly
The following tools are necessary:
•
5 mm Umbraco key
•
Caulking gun (for the stove cement)
Casa is delivered as standard with the flue outlet collar
on the top. In order to change to a back mounted flue
outlet (FIG 2 1-8):
1. Remove the entire loose lid on the top
2. Unscrew the collar with a 5 mm Umbraco key
3. Remove the perforated plate in the surround
4. Remove the perforated plate in the heat shield
5. Unscrew the cast iron lid
6. Screw in place the collar on the posterior flue outlet
7. Screw in place the cast iron lid on the top outlet
8. Place the top lid
Functions (FIG 3 1-5)
1. The door is opened by pulling the handle out and up
2. The ash tray is pulled out in front
3. The ash grate is shoved in and out in order to
remove ashes from the burn chamber
4. The air vent control is adjusted by turning the
wheel under the door in front
5. The hatch under the door is opened by a gentle
push on the right side of the door
Operational Control
When the stove is in position, control that all functions
are easy to manoeuvre and appear satisfactory.
Air vent control
Left position
Middle position
Higher position
Door
Handle turned downward
Handle turned upward
English
Closed
Opened normally
Fully opened
Closed
Opened
17