the chimney. Recommended effective chimney height
is minimum 4 meters with a diameter of 150 – 200mm.
The diameter of the chimney should never be less than
that of the flue/chimney collar.
nominal heat output, see technical table
The draught increases when:
•
The chimney becomes warmer than the outside air
•
The active length of the chimney over the hearth
increases
•
Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the stove,
as the chimney does not heat up well
such cases you may want to contact professional for
evaluation of possible measures. Draught that is too
strong can be controlled with a damper. If necessary,
contact a chimney sweeper.
Air supply
A set for fresh air supply is available as accessory.
This will ensure that the air supply to the combustion
chamber is less affected by ventilation systems,
kitchen fans and other factors which can create a
down-draught in the room. In all new construction, we
strongly recommend that it is designed and prepared for
direct supply of outside air. In older houses, the use of
fresh air supply set is also
air supply can cause down-draught and thereby low
combustion efficiency and the problems that this
entails: soot stains on the glass, inefficient use of the
wood and a soot deposits in the chimney.
Dimensional drawing
The illustrations indicate the approximate centre height
of the recess for the flue. Consider possible inclination
of the flue prior to perforating the chimney. Distortions
in floors and walls may also influence the height. Place
the stove for accurate height and positioning of the flue/
chimney connection.
Warning! Keep the air intakes, supplying
combustion air, free from blockage.
If the requirements for ventilation are
NOT complied with, the product can overheat.
This can cause a fire.
Warrning! Extractor fans when operating
in the same room or space as the appliance
may cause problem.
For your own safety, comply with the assembly instructions.
All safety distances are minimum distances. Installation of the
stove must comply with the current rules and regulations of
the country where the product is installed. Nordpeis AS is not
responsible for wrongly assembled stoves.
Subject to errors and changes.
For the latest updated version go to www.nordpeis.com.
10
For draft requirements at
enough. In
recommended.
Insufficient
2. Technical Information
The stoves from Nordpeis have secondary combustion
and are clean burning. The combustion takes place in
two phases: first the wood burns and then the gases
from the fumes are lit by the hot air. This ensures that
these new stoves have minimal emissions of soot
particles and unburnt gases (such as CO) and are
thus better for the environment. Clean burning stoves
require a small amount of wood in order to obtain a
good heat output. Use exclusively clean and dry wood.
We recommend seasoned hardwood with a moisture
content between 16% and
Material
Surface treatment door/
doorframe
Fuel
Operating range
Efficiency
CO % @ 13% O
2:
Draught system
Combustion system
Heating area
Flue outlet:
Flue
Flue gas temperature
Weight Quadro 1
Weight Quadro 2
Weight Quadro 3
Weight Quadro High To
Air supply requirements
(m³/h)
Fuel charge
Refueling interval
Opening of the air vent
control
Operation:
* Intermittent combustion refers to normal use of a fireplace,
i.e. new wood is inserted when the previous load has burned
down to ember
Warning: If the requirements for ventilation are
NOT complied with, the cooling airflow around the
product will be considerably reduced and
the product can overheat.
This can cause a fire.
3. Distance to combustible material
Ensure that the safety distances are respected
(FIG 2).
When connecting a steel chimney to the top outlet use
the security distances required from the manufacturer.
GB
20%.
Cast iron / sheet steel
Heat resistant varnish
Wood logs, 30 cm
6 kW
80 %
0,09
Air vent control
Secondary combustion
(clean burning)
45-120 m²
Top and rear
Inner Ø 150 mm
277 °C
104 kg
113 kg
118 kg
14 kg
13
1,4 kg
50 min
33%
Intermittent*