iNSTAllATiON
Specification
15.3 Fault conditions
WARNING Burns
In the case of a fault, temperatures up to the high limit
safety cut-out limit can occur (see chapter "Specifica-
tion / Data table").
15.4 Data table
Hydraulic data
Rated capacity
Surface, indirect coil
Application limits
Maximum DHW temperature with heat pump
Maximum DHW temperature with emergency/booster heater
Permissible maximum DHW temperature inside the cylinder
High limit safety cut-out
Heat source min./max. application limits
Minimum installation room volume (recirculation air mode, general domestic use)
Maximum permissible operating pressure, cold water/DHW
Min./max. conductivity, drinking water
Output details to EN 16147
Nominal DHW temperature (EN 16147)
Nominal load profile (EN16147)
Reference DHW temperature (EN 16147 / A20)
Draw-off hot water temperature (EN 16147 / A15)
Draw-off temperature (EN 16147 / A7)
Maximum available nominal DHW volume at 40 °C (EN 16147 / A20)
Maximum available nominal amount of DHW at 40 °C (EN 16147 / A15)
Maximum available amount of DHW at 40 °C (EN 16147 / A7)
Rated heating output Prated (EN 16147 / A20)
Rated heating output Prated (EN 16147 / A15)
Rated heating output Prated (EN 16147 / A7)
Heat-up time (EN 16147 / A20)
Heat-up time (EN 16147 / A15)
Heat-up time (EN 16147 / A7)
Power consumption, standby period (EN 16147 / A20)
Power consumption, standby period (EN 16147 / A15)
Power consumption, standby period (EN 16147 / A7)
COP (EN 16147 / A20)
COP (EN 16147 / A15)
COP (EN 16147 / A7)
Heat output
Average heating output (A20 / W10-55)
Average heating output (A15 / W10-55)
Average heating output (A7 / W10-55)
Power consumption
Average heat pump power consumption (EN 16147 / A20)
Average heat pump power consumption (EN 16147 / A15)
Average heat pump power consumption (EN 16147 / A7)
Max. heat pump power consumption (excl. start-up period)
Power consumption, emergency/booster heater
Max. power consumption heat pump + emergency/booster heater
Energy data
DHW heating energy efficiency class (load profile), indoor air
Coefficient of performance (COP)
Coefficient of performance at A15/W15-55 (EN 255)
COP at A15/W15-45 (EN 255)
Electrical details
Power supply
Permissible voltage range, external signal transducer
30
| SHP-A 220-300 Plus
SHP-A 220 Plus
238633
l
220
m²
°C
65
°C
65
°C
°C
92
°C
+6/+42
m³
13
MPa
0,8
μS/cm
100-1500
°C
55
L
°C
52,6
°C
52,7
°C
54,0
l
278
l
277
l
254
kW
1,60
kW
1,45
kW
1,01
h
6,06
h
6,65
h
8,78
kW
0,022
kW
0,027
kW
0,035
3,55
3,20
2,68
kW
1,9
kW
1,6
kW
1,3
kW
0,5
kW
0,5
kW
0,5
kW
0,65
kW
1,50
kW
2,15
A+ (L)
3,42
3,78
1/N/PE 220-240 V
50/60 Hz
~ 220-240 V 50/60 Hz
SHP-A 300 Plus
SHP-A 300 X Plus
238634
302
65
65
92
+6/+42
13
0,8
100-1500
55
XL
54,4
54,1
54,2
395
412
410
1,52
1,63
1,14
9,05
8,83
12,52
0,024
0,028
0,040
3,51
3,26
2,79
1,9
1,6
1,3
0,5
0,5
0,5
0,65
1,50
2,15
A+ (XL)
3,82
4,22
1/N/PE 220-240 V
1/N/PE 220-240 V
50/60 Hz
~ 220-240 V 50/60 Hz
~ 220-240 V 50/60 Hz
www.stiebel-eltron.com
238635
291
1,3
65
65
70
92
+6/+42
13
0,8
100-1500
55
XL
54,4
52,5
52,6
371
387
381
1,43
1,41
1,07
9,05
9,60
12,43
0,028
0,032
0,044
3,51
3,30
2,75
1,9
1,6
1,3
0,5
0,5
0,5
0,65
1,50
2,15
A+ (XL)
3,82
4,22
50/60 Hz