Télécharger Imprimer la page

Güde GD 20 I Mode D'emploi Original page 12

Chauffage au fioul

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Guarantee
A warranty period of 12 months applies to commercial use
and 24 months apply to private use and commences on
the day of purchase of the device.
Warranty applies exclusively to failures due to defective
material or workmanship. An original sale slip with
indication of date of sale must be presented in case of
claiming for the warranty rights.
Warranty does not cover unprofessional use such as
device overload, violent use, damage caused by third party
or foreign materials, failure to comply with operations and
assembly manual, and normal wear and tear.
Transport
CAUTION
Before transporting the appliance:
Switch the appliance off as instructed in the previous
paragraph; unplug it and let the hot-air generator cool
down.
Make sure the tank lid has been closed safely before lifting
or transferring the appliance.
The appliance can easily be transferred by the handle and
drawn forward.
Troubleshooting
Failure
Possible
cause
Fan not
1. No power
starting and
supply
flame not
2. Engine
beginning to
winding is
burn.
burnt out or
broken
Fan starting
1. Ignition
and flame
system is not
not beginning
working.
to burn or
2. Flame
going out
control is
immediately.
faulty.
3. Photocell is
not working.
4. No or
insufficient
amount of oil
getting to the
burner.
5. Electric
valve is not
working.
Fan starting
1. Combustion
and flame
air is not
beginning to
sufficient.
burn but
2. The fuel
used is dirty
smoking.
or contains
water.
3. Air in the fuel
piping.
4. Oil volume in
the burner is
insufficient.
Removal
1.
Check the power supply
properties. Check the
switch functionality and
position.
Check the safety fuse.
2.
Switch off the engine.
1.
Check the ignition
cabling to the electrodes
and transformer. Check
the position of the
electrodes. Check
whether the electrodes
are clean. Replace the
ignition transformer.
2.
Replace the appliance.
3.
Clean or replace the
photocell.
4.
Check the pump-engine
connection. Check
whether there is air in
the fuel piping. Check
the hoses and filter
sealing. Clean the
nozzle and replace it if
necessary.
5.
Check the plugging.
Clean the electric valve
and replace it if
necessary.
1.
Remove all possible
obstacles and
obstruction at the air
inlet or outlet. Check the
air inlet ring gauge
position. Clean the
screen.
2.
Replace the used oil
with fresh oil. Clean the
oil filter.
3.
Check the tightness of
hoses and the oil filter.
5. Too much oil
in the
burner.
Generator
1.
Electric
not pausing.
valve
sealing is
defective.
2.
Fan
thermostat
is
defective.
Flame
1.
Insufficient
blasting off
air inlet in
the appliance
the
in the front.
combustio
n
chamber.
Behaviour in case of emergency
Provide necessary first aid treatment corresponding to the
injury nature and seek qualified medical help as soon as
possible.
Protect the injured person from other injuries and calm
him/her down.
First aid kit must always be available in the place of
your work in case of accident in accordance with DIN
13164. Material taken out of the first aid kit needs to be
supplemented right away.
If help is needed,
please provide the following details:
1.
Place of accident
2.
Accident nature
3.
Number of injured persons
4.
Injury type
Disposal
The disposal instructions are based on icons placed on the
appliance or its package. The description of the meanings
can be found in the "Marking" chapter.
Transport package disposal
The package protects the appliance against damage
during transport. Packing materials are usually chosen
depending on their environmental friendliness and disposal
method and can therefore be recycled.
Returning the package to material circulation saves raw
materials and reduces waste disposal costs.
Parts of packages (e.g. foils, styropor) can be dangerous
to children. Risk of suffocation!
Keep parts of packages away from children and dispose
them as soon as possible.
Old batteries to be delivered to car repair
services and appropriate collection centres only.
Operating staff requirements
The operator must carefully read the Operating
Instructions before using the appliance.
Qualification
No special qualification is necessary for using the
appliance apart from detailed instruction by a qualified
person.
12
4.
Check the pump
pressure value. Clean or
replace the nozzle.
5.
Check the pump
pressure value. Replace
the nozzle.
1.
Replace the electric
valve body.
2.
Replace the fan
thermostat.
1.
Check the fan. Check
the air inlet.
7

Publicité

loading

Ce manuel est également adapté pour:

Gd 30 i8510185103