20 Progress
Problem and alarm code
Malfunction of the water level detection
sensor.
The indicator
termittently.
The light related to the start button
flashes continuously.
Malfunction of the wash pump or the
drain pump.
The indicator
termittently.
The light related to the start button
flashes continuously.
The temperature of the water inside
the appliance is too high or malfunction
of the temperature sensor occurred.
The indicator
termittently.
The light related to the start button
flashes continuously.
Technical malfunction of the appliance.
The indicator
intermittently.
The light related to the start button
flashes continuously.
The level of water inside the appliance
is too high.
The indicator
intermittently.
The light related to the start button
flashes continuously.
The appliance stops and starts more
times during operation.
The programme lasts too long.
Small leak from the appliance door.
flashes 4 times in‐
flashes 5 times in‐
flashes 6 times in‐
flashes 12 times
flashes 15 times
Possible cause and solution
Make sure that the filters are clean.
Switch the appliance off and on.
Switch the appliance off and on.
Make sure that the temperature of the inlet wa‐
ter does not exceed 60°C.
Switch the appliance off and on.
Switch the appliance off and on.
Switch the appliance off and on.
Make sure that the filters are clean.
Make sure that the outlet hose is installed at the
right height above the floor. Refer to the installa‐
tion instructions.
It is normal. It provides optimal cleaning results
and energy savings.
If the delayed start option is set, cancel the de‐
lay setting or wait for the end of the countdown.
The appliance is not levelled. Loosen or tighten
the adjustable feet (if applicable).
The appliance door is not centred on the tub.
Adjust the rear foot (if applicable).