18. Check the efficiency of the LED flashing lights integrated in the
barrier body and the integrity of the transparent covers.
19. Check the integrity and efficiency of any accessories installed:
APM mobile support, APFX fixed support, SKIRT2 racks, joint for
articulated bar, etc. Make sure that they are firmly secured.
20. Check that the automation system is working properly and that
the bar motion is smooth. Ensure that the opening and closing
speeds are adequate for the length of the bar, with gradual accele-
ration in the initial phase and progressive slowing down in the final
phase of the travel, in order to avoid dangerous jolts and swaying
that could affect the safety and life of the bar.
8.2 - Scheduled replacements
The components that make up the ALTK automation system have been
designed to last, under normal conditions of use, for the entire working
life of the product without any special action being required.
However, some of them are directly linked to system safety and there-
fore, it is recommended to regularly replace them according to the fol-
lowing indications:
1. Replace the balancing spring(s) every 2 years or every 200,000
opening/closing cycles
2. Replace: - the aluminium bar AST3F, ASTL4, ASTL4J, ASTL6,
ASTL6J every 5 years or every 500,000 opening/closing cycles
- the aluminium bar AST3F, ASTL5, ASTL8, ASTL6J every 3 years or
every 250,000 opening/closing cycles
- the articulated bar AS-SNO3 every 2 years or every 150,000
opening/closing cycles
3. Replace the gearmotor every 5 years or every 500,000 opening/
closing cycles
26
21. Ensure compliance with the regulation provisions, in particular
the requirements relating to user safety contained in the EN 12453
standard (see paragraph 8.1 "Testing")