8
pre setup
tP.r.
9
pre time
C.Le.
10
CLEAR ANCE
de.a.
11
hold torun
IN.D.
12
indic light
se.r.
13
cycle servi
se.f.
14
setup servi
15
LED TYPE
EL.T.
16
elect time
ST.P.
17
boost setup
En.C.
18
encod setup
DE.F.
19
motor setup
Defines pre-flashing modes of FLASH, IND/ELEC and
LED outputs if FLASH SETUP = 0/1
0 = pre-flashing before each opening and closing
manoeuvre
1 = pre-flashing before each closing manoeuvre
2 = pre-flashing before each opening manoeuvre
iND/ELEC output (green light)
ATTENTION !
pre-flashes on opening only; LED output (red light) pre-
flashes on closing only
Defines the duration of the pre-flashing
if set to 0, no pre-flashing is
ATTENTION !
performed
Early open position (with respect to the mechanical
stop); the value is expressed as a percentage of the total
travel stroke
Enables the "man present" function on SBS, OPEN and
CLOSE inputs
when this function is enabled, the
ATTENTION !
operation of the remote controls is inhibited
Defines the behaviour of the IND/ELEC and LED outputs
(barrier lights)
5 = MODE 1
• barrier closed, LED output active (red LEDs)
• barrier open, IND/ELEC outputs (green LEDs) and
LEDs (red LEDs) not active
• during opening, IND/ELEC output flashing
(green LEDs)
• during closing, LED output (red LEDs) flashing
• barrier stopped in intermediate position, LED output
flashing (red LEDs)
6 = MODE 2
• barrier closed, LED output active (red LEDs)
• barrier open, IND/ELEC outputs active (green LEDs)
• during opening, IND/ELEC output flashing
(green LEDs)
• during closing, LED output (red LEDs) flashing
• barrier stopped in intermediate position, LED output
flashing (red LEDs)
Specifies the number of manoeuvres before the
maintenance request signal (if 0, the function is disabled)
signalling is via the FLASH output;
ATTENTION !
if closed, it flashes continuously.
Enable maintenance request signalling
0 = deactivated
1 = active
Set to 0 if the old CTLIGHT2 module is used
If FLASH SETUP = 3; activation time (in seconds)
of the electric lock connected to the IND/ELEC output
If FLASH SETUP = 4; demagnetisation time (in seconds)
of the magnetic lock connected to the IND/ELEC output
If active, maximum acceleration at start-up
0 = deactivated
1 = active
Displays the encoder type in use
0 = virtual encoder
1 = physical encoder
Defines the type of automation on which the control unit
is installed and resets the default values.
0 = sliding gate TUS4324 (see the dedicated manual)
1 = sliding gate SUN5324 (see the dedicated manual)
2 = sliding gate SUN7324/TUS7324 (see the dedicated
manual)
3 = sliding gate SUN11324M/TUS11324 (see the
dedicated manual)
4 = 4m/6m barrier
5 = 8m barrier
6 = overhead door (see the dedicated manual)
0
0
2
0
0
20
0
0
30
0
0
900
6
5
6
x 1000
10
0
200
0
0
1
1
0
1
4
1
10
0
0
1
1
1
1
2
2
5
EN
s
%
s
cicli
s
21