6 - CONTROL UNIT
6.1 - Description of the control unit
The CT10324 and CT10324F control unit is the most modern,
efficient system for the control of Key Automation motors for the bar-
riers. All other, improper, use of the control unit is forbidden.
1
M +
M -
V+
22
ENC
NEG
12
6.2 - Description of the connections
1- Motor power supply (M+ and M-)
2- Central power connector
3- Connection of flash light, courtesy light, barrier open indicator
light/electic lock
4- 24 Vac connector for control and safety devices
5- 24 VDC power supply (not regulated) for safety devices
(remote safety edge, photocells)
6- Inputs for safety devices (STOP/Safety edge, photocells)
8- Status LED indicators: EDGE/STOP, PH2, PH1 safety devices
(red); OPEN, CLOSE, PAR, SBS actuator inputs (green)
9- Deactivation of EDGE/STOP, PH1, PH2 safety devices
10- Limit switch inputs
11- Limit switch status LED indicators (red)
6.3 - Models and technical characteristics
CODE
DESCRIPTION
CT10324F
24V control unit for ALT3 barrier motor
CT10324
24V control unit for ALT4Kand ALT6 barrier motor
- Short-circuit or overload protection for the outputs of accessories
connected to the control unit.
- Obstacle detection.
- Automatic learning of working times.
21
13
POWER
SUPPLY
2
3
The 5-digit/14-segment display on the CT10324 and CT10324F
control units makes it easy to read the acronyms, facilitating pro-
gramming and monitoring the automation; the menu structure ma-
kes it easy to set working times and operating modes.
10
19
14
17
11
15
9
16
8
ON
STOP
PH2
PH1
OPEN CLOSE PAR
4
5
6
7
12- KBP/KBPN buffer battery (optional)
13- Timed 1.6AT fuse
14- 5-digit/14-segment display
15- STEPPING SBS button ( )
16- UP ( ) button
17- MENU ( ) button
18- DOWN ( ) button
19- Radio functionality or error reporting LED indicator (green)
20- Antenna
21- SBK, set-up for connection to energy saving module
22- Encoder connection
23- Connector for KUBE interface / PowerBus (optional)
- Deactivation of EDGE/STOP, PH1 and PH2 safety devices via dip
switches: it is not necessary to jumper the terminals of non-instal-
led safety.
ANT
SHIELD
20
18
23
SBS
EN
11