bient temperature. The connection to AC power must be done by experienced
people and according with existing laws. The installer is responsible of the correct
connection according with safety rules.
3.3
CONNECTIONS TO THE HEATING SYSTEM
Picture 5 – Connections of the boiler for the heating system
1
Connection detector of auxiliary
thermostat (optional) Ø 1/2'' female
2
Going connection Ø 1''1/4 female
3
Connection for thermal discharge
detector (optional) Ø 1/2'' female
Thermal stoves are endowed with some conducts that you must connect for the
correct working of the device, these are the going conduct, the return conduct
and the discharge conduct. The discharge conduct is necessary to allow the com-
plete emptying of the boiler in case of necessity. There are also some conducts and
connections that are facultative and serve for auxiliary or safety devices. These are
the thermal discharge circuit conducts, the connection of the detector for thermal
discharge device and the connection for an auxiliary thermostat. If you do not use
these conducts you must close them.
4
Connection for thermal discharge
circuit (optional) Ø 1/2'' male
5
Return connection Ø 1''1/4 female
6
Connection discharge Ø 1/2 female
7
External primary air entrance (facultative)
49