EXTRACTOR FAN MAINTENANCE
● Cleaning the extractor fan :
For cleaning, use
a cloth moistened with neutral li-
ONLY
quid detergents.
DO NOT USE CLEANING UTENSILS OR TOOLS!
Avoid the use of products containing abrasives.
DO NOT
USE ALCOHOL!
●
Grease filter maintenance:
Traps grease particles generated by cooking.
Must be cleaned once a month (or when indicated by the
filter saturation indication system), with non-aggressive de-
tergents, either by hand or in the dishwasher at low tem-
peratures and in a short cycle. When cleaned in the dish-
washer, the metal grease filter may discolour, but its filter-
ing characteristics remain unchanged.
●
Ceramic activated carbon filter maintenance (For
Recirculating Version only):
Traps unpleasant odours generated by cooking. The
product comes with a set of odour filters.
The saturation of the odour filters can occur after some-
what prolonged use depending on the type of cooking and
how regularly the grease filter is cleaned. The odour filters
can be thermally regenerated every 2/3 months in an oven
pre-heated to 200°C for 45 minutes. The correct regenera-
tion of the filter ensures that it can constantly filter effi-
ciently for 5 years.
Please note! Do not place the filters on the floor of the
oven but rather in a tray, positioned at an intermediate
height.
67