2-times option for torch trigger
Permit to define 2 different ways
to control the retrigger of machine during
slope down. For detailed description of
different behaviours see the following
diagrams.
0 = Immediate return to welding current
(default)
1 = Return to welding current by slope up.
to control the torch trigger when the
machine is set as 4Times stroke (Lift or
HF). For detailed description of different
behaviours see the following diagrams.
Select a value in the range 0...2 (1=default
setting).
0 = disabled
1 = enabled (factory settings)
Remote Control Option
It is possible to select 4 different
ways depending from the external device
connected to 8-pole plug (option)
Welding current can be controlled up to
previous SET or to MAX.
External reference voltage can be 0-10V or
0-5V (Condition 2 & 3 presents lower
resolution)
0 = 0-10V
1 = 0-10V
2 = 0-5V
3 = 0-5V
All above settings are not modified via Reset.
27
4-times option for torch trigger.
Permit to define 3 different ways
Dynamic Oxide Control. (for AC
welding)
Imin to ISET (factory settings)
Imin to IMAX
Imin to ISET
Imin to IMAX