MSW Motor Technics S-POWER MPPT 5000 Manuel D'utilisation page 69

Publicité

English
Alarm code
meaning
50
Battery open
51
Battery Under
52
Battery low
Battery
53
charge short
55 Over charge
Over
57
Temperature
58
fan lock
59 EEPROM fail
overload
60
warning
Abnormal
generator
61
waveform
PV Energy
62
Weak
EN
Related actions
Trigger condition
Alarm, battery
The battery voltage is
does not charge
lower than 8V / section
Alarm, battery
Battery voltage is
low voltage
shutdown or no
10.5v/section (default)
startup
Depending on BAL setting
give an alarm
The battery voltage is less
Alarm, battery
than 5V and the charging
does not charge
greater than 4a
The battery voltage is
Alarm, battery
higher than the set
does not charge
The temperature sensor of
Alarm, battery
PFC or inv is higher than
does not charge
the set value
Alarm. If one fan
No fan speed signal
fails, the other fan
will run at full
speed
EEPROM read / write
give an alarm
Alarm, battery
does not charge
Alarm,
Abnormal generator
continuous
waveform detection
operation in
battery mode
When the battery is not
Turn off PV output
connected, the bus voltage
and charge
is lower than
the set value
Recovery
conditions
Recoverable
(10V / section)
Recoverable
lower than
(10V / cell + 0.2
* n (number of
battery cells))
Recoverable
(action point +
0.2v/section)
Unrecoverable
current is
recoverable
value
The
sensor of PFC or inv
is lower than
the set value
recoverable
detected
Unrecoverable
failed
Recoverable
Load > 102%
(load < 97%)
recoverable
Recover after
Fault alarm
give an alarm
give an alarm
give an alarm
give an alarm
give an alarm
temperature
give an alarm
give an alarm
give an alarm
give an alarm
give an alarm
give an alarm
10mins