When the battery type is set to cus (customer setting type), the low voltage point of the battery can
be modified. 3k-vml-24v, settable range [21,27]
5k-vmh-48v, settable range [42,54]
When the battery type is set to Lib (lithium battery type), the low voltage point of the battery can be
modified. The default setting of 3k-vml-24v is 23.8v, and the settable range is [20.6,25.0]
The default setting of 5k-vmh-48v is 47.6v, and the settable range is [41.2,50.0]
Battery shutdown point
bAU
Figure 1-29 battery shutdown point setting page
Function Description: battery low voltage shutdown point setting function. Setting conditions: all
States can be set.
explain:
bAU:battery Under
It cannot be set when the battery definition mode is AGM (lead-acid battery type) or FLD (water
injection battery type). The initial default setting of 3k-vml-24v is 21V
The initial default setting of 5k-vmh-48v is 42V
When the battery type is set to cus (customer setting type), the battery shutdown point can be
modified. 3k-vml-24v can be set to [20,24]
5k-vmh-48v settable range is [40,48]
When the battery type is set to Lib (lithium battery type), the battery shutdown point can be
modified. 3k-vml-24v is set to 23v by default, and the settable range is [20,24]
5k-vmh-48v is set to 46v by default, and the settable range is [40,48]

Publicité