Publicité

3
Bus low
Battery Over
Current
4
Over
5
temperature
6
Battery high
Bus soft Fault Fault mode
7
Bus short
8
Fault
INV soft Fault Fault mode
9
INV over
10
voltage
INV under
11
voltage
12
INV short
Negative
13
power
overload
14
fault
EN
The bus is lower than the
Fault mode
set value
The instant value of the battery
Fault mode
current exceeds 580A, and
immediately
protects
The temperature sensor of PFC
or INV is higher than the set
Fault mode
value of over
-temperature settings
The battery voltage is higher
Fault mode
than the set value
DC soft -up voltage with
DC does not meet the set value
When working normally, the
Fault mode
bus is instantly lower
than the set value
After a period of time, the
inverted softening starts for a
period of time, it still cannot
reach the rated
output voltage
In the battery mode, the product
Fault mode
voltage is higher
than the set value
In the battery mode, the
Fault mode
product voltage is lower
than the set value
The product voltage is instantly
Fault mode
less than the set value, and the
current is
greater than the set value
The inverse power is less
Fault mode
than the set value for a period
of time
The load is exceeded of the
Fault mode
specification
Cannot recover
Cannot recover
After restarting
enable, the failure
restarts cannot be
recovered after
three failures
Recovery
Cannot recover
Cannot recover
Cannot recover
Cannot recover
Cannot recover
After the failure
restarts three
failures, it cannot
be restored
Cannot recover
After restarting
enable, the failure
restarts cannot be
recovered after
three failures
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault