EN
Figure 1-31 floating charge mode voltage point setting page
Function Description: floating charge voltage point setting function. Setting conditions: all States can
be set.
explain:
bFL:battery Float
It cannot be set when the battery definition mode is AGM (lead-acid battery type) or FLD (water
injection battery type) The initial default setting of 3k-vml-24v is 27V
The initial default setting of 5k-vmh-48v is 54V
Setting the battery type to cus (customer setting type) can modify the battery floating charge point.
3k-vml-24v can be set to [26.6,27.8]. The voltage at the constant voltage point needs to be greater
than the voltage at the floating charge point.
5k-vmh-48v can be set to [48,60]. The voltage at the constant voltage point needs to be greater
than the voltage at the floating charge point.
When the battery type is set to Lib (lithium battery type), the constant voltage charging point can be
modified.
The default setting of 3k-vml-24v is 27.6v, and the settable range is [24,28]. The voltage at the
constant voltage point needs to be greater than the voltage at the floating charge point.
The default setting of 5k-vmh-48v is 55.2v, and the settable range is [50,58]. The voltage at the
constant voltage point needs to be greater than the voltage at the floating charge point.
Setting of mains low voltage point
LLV
(
)