Charging priority
CHP
(
Function Description: set the charging priority of product.
Setting conditions: all States can be set and take effect immediately.
explain
:
There are four options for charging priority. The default is PNG (PV and grid): PV and grid are charged
at the same time; The second is OPV (only PV): only PV charging; The third is GRD (grid): municipal
power charging is preferred; The fourth is PV: PV gives priority to charging
Mains charging current
Figure 1-17 maximum charging setting page of mains power
Function Description: set the maximum rechargeable current of the product. Setting conditions: all
States can be set.
explain
:
RCC: grid charge current, the maximum charging current of mains power is set to 40A by default,
and the setting range is [1,60a] (3K vml-24v)
RCC: grid charge current, the maximum charging current of mains power is set to 30A by default,
and the setting range is [1,80a] (5K vmh-48v)
)
Figure 1-16 charging priority setting page
RCC
(
)