SAFET Y N OT ES
W A R N I N G : To avoid the risk of product
failure, propert y damage, and personal
injury, do the following:
This product should be installed by a licensed pro-
fessional plumber.
This product is for use with drinking water only.
Install this faucet in an accessible area. Keep away
from external heat sources. The hoses should not be
allowed to rub against other items under the sink, such
as a trash bin.
The hot and cold supply hoses are for use with
⅜ stops. If your stops are a different size, install
new ones. Using anything other than ⅜ stops may
result in product failure and property damage.
The hoses on this faucet must not come into con-
tact with detergents or other materials containing
chlorine bleach, lye, hydrochloric acid, formic
acid, acetic acid, or other harsh chemicals as they
can damage the hose. Do not store such materials
under the sink where this faucet is installed.
Inspect the hoses for leaks or corrosion immediate-
ly after installation and every six months thereafter.
Replace the hose if signs of leaks or corrosion are
detected.
Refer to the Cleaning Recommendations on page
18 when selecting a cleaning agent for this
product. Do not use cleaning products contain-
ing chlorine bleach, lye, hydrochloric acid, formic
acid, acetic acid, or abrasives.
Failure to follow these instructions may result
in product failure and propert y damage, and
may void the warrant y.
T EC H N IC A L I N FO RMAT I O N
Water pressure
Recommended
15 - 75 PSI (0.1 - 0.5 MPa)
Maximum
Hot water temp.
Recommended
120°-140° F (48° - 60° C)*
Maximum
Max. flow rate
0.08 gallons (0.3 liter) per cycle**
Hole size in mounting surface
Max. depth of mounting surface
Battery
Automatic shutoff
*
Please know and follow all applicable local plumbing
codes when setting the temperature on the water
heater.
** 10 second maximum cycle time
*** This is the maximum amount of time the faucet will run
while a hand is within range of the sensor.
INSTA LL AT ION CO N S ID E R ATI ON S
⁄ This unit should be installed by a licensed, professional
plumber.
⁄ Read over these instructions thoroughly before begin-
ning installation. Make sure that you have all tools and
supplies needed to complete the installation.
⁄ IMPORTANT: Keep this booklet and the receipt (or oth-
er proof of date and place of purchase) for this product
in a safe place. The receipt is required should it be
necessary to request warranty parts.
2
⁄ Protection against backflow is provided by two check
valves. The check valves should be inspected yearly
and replaced when dirty or worn.
This product is intended only for public spaces.
⁄ This faucet does not include a drain or a pull rod.
⁄ Flush the hot and cold supplies thoroughly before in-
stalling the faucet. Damage to the faucet caused by
debris is not covered under the warranty.
⁄ The hot and cold supplies should be of equal pressure.
⁄ The faucet should not be used with a continuous flow
water heater.
⁄ Do not install the faucet on a sink with a raised edge.
⁄ Strong light sources should not shine directly on the sen-
sor window of the faucet.
⁄ The faucet should only be used with the battery pack
supplied by Hansgrohe. Do not attempt to use any
other battery pack.
⁄ The faucet incorporates automatic range adjustment --
the sensor automatically adjusts itself to local conditions
(lavatory, brightness, etc.)
⁄ The distance between the switch on/off point to the
faucet is approx. 6¼" - 8" under normal conditions.
The detection area may be less for dark, non-reflective
objects, or greater for bright, highly reflective objects.
If the sink is very small or highly reflective, fol-
low the RANGE REDUCTION INSTRUCTIONS
(page 11). When the faucet is in reduced
range mode, the LED in the sensor window will
flash while the faucet is not in use.
⁄ Drops of water or condensation on the sensor window
may cause the faucet to run.
The spray pattern will be unattractive immediately
after installation or service, due to air in the faucet.
After the faucet is used 10 - 15 times, the spray
pattern will clear.
145 PSI (1 MPa)
⁄ At the start of operation, or after maintenance, function
of the faucet may be delayed due to reflections during
adjustment of the operating distance. The faucet will au-
158°F (70° C)*
tomatically calibrate itself. The self-calibration will start
0.5 GPM (1.9 L/min)
after 10 - 15 minutes.
1⅜" (35 mm)
⁄ Hansgrohe recommends not to use as drinking water
1⅝" (40 mm)
the first half liter (approximately 1 pint) flowing from the
CR-P2 / 6 V Lithium
faucet in the morning, or after prolonged non-use.
after 10 seconds***
H YGIE N E RIN SE
The hygiene rinse opens the faucet for 10 seconds every
24 hours following the last use.
To enable or disable the hygiene rinse:
⁄ Disconnect the electrical plug connection between fit-
ting and battery housing. During this time, briefly reach
with your hand into the detection area of the sensor
window so that the capacitor discharges. Restore the
power connection after 10 seconds.
⁄ The LED blinks to indicate the software version (e.g.
blinking once = software version 1).
⁄ The LED will come on constantly while the faucet cali-
brates.
⁄ Cover the sensor window completely with your hand or
a piece of white paper for 5 - 10 seconds. Water will
flow from the faucet for 5 seconds.
E N G L I S H
WAIT FOR THE LED TO GO
OUT.
⁄ Uncover the sensor window.
⁄ The currently enabled mode is indicated by the flash-
ing of the LED: 1 x = hygiene rinse is enabled, 2 x =
disabled.
⁄ A subsequent change of operating mode is possible
again after calibration.
⁄ The fitting returns to normal operation 60 seconds after
the last change of operating mode.
PER M ANENT R INSE
After setting the parameters for the hygiene rinse or mak-
ing a net reset, wait for approx. 100 seconds before you
can enable the "Permanent rinse" function.
⁄ Cover the sensor window completely with your hand or
a white piece of paper.
⁄ The faucet opens briefly and then closes immediately.
When the faucet opens again after approx. 5 seconds,
remove the hand or the paper from the sensor.
⁄ Permanent rinse is enabled for 3 minutes and can be
interrupted at any time by a movement in the sensor
range.
THER MAL DI SI NFECTION
Thermal disinfection must only be carried out by
qualified personnel.
⁄ Risk of scalding with thermal disinfection!
⁄ The cold water stop must be closed during thermal
disinfection.
⁄ Afterwards, "Permanent rinse" can be enabled.
NET R ESET
⁄ A "net reset" returns the faucet to the original factory
settings.
⁄ Interrupt the voltage supply to the faucet.
⁄ Briefly reach into the sensor range of the faucet to dis-
charge the capacitor.
⁄ Wait for approx. 10 seconds, then plug the connectors
in again.
The faucet will re-adjust during the next 30 sec-
onds. Do not reach into the sensor range during
this period of time.