Télécharger Imprimer la page

Beurer BF 880 Mode D'emploi page 12

Masquer les pouces Voir aussi pour BF 880:

Publicité

weight is more than 3 kg apart, use the
correct scale user and wait 3 seconds.
3. The following values will then appear one after the other.
Body mass index (a healthy value is 18.5 – 25)
Body fat percentage (a healthy value is 16 – 28% for
women and 11 – 23% for men)
Muscle percentage (a healthy value is 27 – 43% for
women and 37 – 57% for men)
For more details of the values, please see the app or the
FAQs at: www.beurer.com
4. If a Bluetooth
or WIFI connection has been established and the
®
user measurements have been successfully taken (e.g. for U: 1), the
values will be transferred to the "beurer HealthManager Pro" app.
This is indicated by the measurement data transfer symbol
the data cannot be transferred, up to 30 values will be stored per
user. As soon as a connection is established, they are transferred
with the next measurements.
• If the automatic scale user detection function is not
working, briefly press the scale with your foot, press
the
button
displayed, and wait 3 seconds. Then take the diag-
nostic measurement.
• To display your most recent diagnostic measurement,
briefly press the scale with your foot, press the
button
repeatedly until your scale user is dis-
4
played, and wait 3 seconds. Then press the
ton
to display the most recent diagnostic measu-
2
rement. To display further measurements, press the
button
2
shown on the display
• If the measurement is carried out with shoes or socks
on, then only the weight is displayed (when the scale
user is recognised, the weight and BMI are displayed
and saved).
5.4 ALTERNATIVE METHOD: creating scale
users without the app
Alternatively, you can also create a scale user directly on the scale
without using the app. This process is not required if the scale has
already been connected to the app.
1. Press and hold the SET button
on the display.
2. Press the SET button
display 1.
3. Use the
button
4
can select from U: 1 to 8). Confirm your selection with the SET
button
.
3
4. "170" flashes on the display. Use the
the height. Confirm with the SET button
5. "30" flashes on the display. Use the
the age. Confirm with the SET button
6.
flashes on the display. Use the
the gender. Confirm with the SET button
7. "Act3" flashes on the display. Use the
your activity level based on how much you exercise (considered
over the long term). (Act1 = none, Act2 = low, Act3 = medium, Act4
= high, Act5 = very high/athletic). Confirm with the SET button
8. "End" appears in the display. Confirm with the SET button
scale user has been created successfully.
button
4
repeatedly until your scale user is
4
again. Up to 30 measurements can be
.
1
for 4 seconds. "unit" appears
3
repeatedly until "on" appears on the
3
to select the scale user you need (you
/
button
.
3
/
button
.
3
/
button
.
3
/
button
to select the
9. "0.0" and the user symbol appear on the display. Take the initial
measurement.
5.5 Deleting scale users
You can delete individual scale users in the "beurer HealthManager
Pro" app.
Alternatively, you can also delete scale users directly on the scale.
To do so, proceed as follows:
1. Press and hold the SET button
on the display.
2. Press the SET button
3. Use the
firm your selection with the SET button
4. Press the SET button
press the
5. "dEL" appears on the display. Confirm with the SET button
. If
11
The scale user has now been deleted.
5.6 Changing the weight unit
You can change the weight unit either using the "beurer HealthMa-
nager Pro" app or directly on the scale:
1. Press and hold the SET button
on the display
2. Use the
unit (kg, lb or stlb). kg = kilograms, lb = pounds, stlb = stones
3. To confirm, press the SET button
switches o .
1
but-
5.7 Deactivating Bluetooth
To deactivate Bluetooth
1. Press and hold the SET button
2. Press the SET button
display 1.
3. Select "oFF" with the
4. To confirm, press the SET button
switches o .
1
Please note that the Bluetooth
NO longer possible. To reactivate it, set it from "oFF" to "on".
6. WHAT IF THERE ARE PROBLEMS?
6.1 Restarting scale
If it is necessary to restart the scale (e.g. scale software freezes).
Remove the batteries briefly.
6.2 Resetting the scale to factory settings
1. Press and hold the SET button
on the display.
to set
2
4
2. Press the SET button
display.
to set
2
4
3. Press the
button.
3
to set
2
4
6.3 Updating scale software
to set
2 4
The app will inform you when a new software update is available.
1. Briefly press on the scale to switch it on.
2. Press and hold the
.
3
matically checks for an update and downloads it. This may take a
. The
3
few minutes. If the update is successful, "PASS" will be displayed.
12
for 4 seconds. "unit" flashes
3
twice until "USEr" flashes on the display.
3
button
to select the scale user to be deleted. Con-
4
repeatedly until "End" appears. Then
3
button
within 5 seconds.
4
for 4 seconds. "unit" appears
3
.
1
button
or
button
to select the desired weight
2
4
repeatedly until the display
3
and WIFI
®
and WIFI, proceed as follows:
®
for 4 seconds.
3
repeatedly until "on" appears on the
3
button
or the
2
repeatedly until the display
3
and WIFI function is then
®
for 4 seconds. "unit" flashes
3
three times until "SET" flashes on the
3
/
button
and confirm "rSt" using the SET
2
4
button
for 15 seconds. The scale auto-
2
.
3
.
3
button
.
4

Publicité