Télécharger Imprimer la page

Beurer BF 880 Mode D'emploi page 13

Masquer les pouces Voir aussi pour BF 880:

Publicité

If the scale is already up to date with the latest software version
"utd" appears.
6.4 Messages and errors
Display
Cause/remedy
Discrepancy
Incorrect zero point (e.g. in the event of a
in weight
change of location or temperature fluctuation):
briefly press on the scale until the current weight
is displayed, then remove your foot so that "0.0"
flashes.
Scale is placed on carpet or uneven ground: the
surface must be hard and level.
PAir
Bluetooth
ring/bonding on your smartphone (note any
messages in the status bar/notification bar), and
confirm the 6-digit pairing code using the SET
button
3
"USE APP" or
The scale can be connected to the app via Blu-
flashing
: do not connect it via the Bluetooth
®
etooth
settings on your smartphone, only via the app.
UnSt
This weight measurement was unstable: stand
still during the measurement.
U: --
The scale was unable to assign the measure-
ment to a scale user: if the automatic scale user
detection function is not working, briefly press
the scale with your foot, press the
repeatedly until your scale user is displayed, and
wait 3 seconds. Weigh yourself again.
BF--
The body fat percentage is outside the measu-
rable range (less than 5% or greater than 70%):
check the user data or change the activity level.
Diagnostic measurement cannot be taken (e.g.
measurement attempted while wearing shoes):
Repeat the measurement barefoot. Otherwise,
only weight values will be displayed and trans-
ferred.
oLd
The maximum weight capacity of 180 kg has
been exceeded: loads must not exceed 180 kg.
Lo
Batteries are flat. Replace the batteries.
Err1
Incorrect password for your selected WIFI net-
work/SSID/router.
Err2
Your router does not have Internet access. The
server cannot be reached.
Er3...
Software update failed: please try again.
Err4
Booting problems: Remove the batteries briefly.
utd
The software is up to date.
There is no WIFI connection to the server for the
no
software update.
needs to be paired: start/allow pai-
®
on the device and on the smartphone.
6.5 WIFI/Bluetooth
Problem
No Bluetooth
connection
Symbol
not displayed
®
button
2
No connection to
server/cloud
Symbol
is not displayed
13
connection problems
®
Cause/remedy
Device is outside the Bluetooth
®
The minimum range in the open is approx. 10
is
m. Walls and ceilings reduce the range. Other
10
radio waves may interfere with the transmis-
sion. Therefore, do not position the scale
near devices such as microwaves or induc-
tion hobs. Ideally, switch o other Bluetooth
devices that are within range.
No Bluetooth
connection to the app.
®
1. Press the SET button
that "USE APP" flashes in the scale dis-
play. Then use the "beurer HealthManager
Pro" app.
2. Switch Bluetooth
and on again. Ensure that the scale is not
being connected via the Bluetooth
of the operating system. If necessary, remo-
ve it from the device list in the Bluetooth
settings and then use the "beurer Health-
Manager Pro" app.
3. Completely close the app (including in the
background). Switch your smartphone o
and on again.
4. Briefly remove the batteries from the scale
and reinsert them. Launch the app.
5. When connecting the scale, check the sta-
tus bar on the smartphone to start pairing/
bonding.
Note: A Bluetooth
®
red for initial use and changing the scale's
settings. The measurements can also be
transferred via Bluetooth
standard application the measurement data
will be transferred via WIFI (without Blue-
).
®
tooth
Eine Bluetooth
zur Inbetriebnahme und Einstellung
der Waage erforderlich. Die Messun-
gen können zwar auch per Bluetooth
übertragen werden, jedoch wird die
Messdatenübertragung in der nor-
malen Standardanwendung per WIFI
(ohne Bluetooth
Check whether your router has an Internet
connection. Check the device settings in the
app.
12
range.
®
®
on the scale so
3
on your smartphone o
®
settings
®
®
connection is only requi-
, but in the normal
®
-Verbindung ist nur
®
®
) stattfinden.
®

Publicité

loading