3.2.7 BLEND WIZARD
TM
In addition to using the profiles and cycles preprogrammed on
the blender, Blend Wizard
can be used to create custom profiles
TM
and cycles. For instructions on using Blend Wizard
develop custom profiles and cycles, visit my.blendtec.com.
3.2.8 BLENDER STATISTICS
Blend cycle counts
To review the total number of cycles run and the number of cycles
run for each button:
1. Press
and
for 1 second to enter the menu.
2. Press
to scroll down to Cycle Counts. Press
3. Press
to scroll through cycle counts.
4. Press
to exit the menu.
Note: The pulse count refers to pulse sets. For example, touching the
pulse button 5 times in a row will register as 1 pulse count. Touching
the pulse button, then a cycle number and then the pulse button will
register as 2 pulse counts.
Diagnostic error log
To review the diagnostic errors that have been logged on the
blender:
1. Press
and
for one second to enter the menu.
2. Press
to scroll down to Diagnostic Counts; press
to select.
3. Press
to scroll to see the number of errors in each category.
4. Press
to exit the menu.
Exporting blender statistics
Exporting blender statistics (cycle counts, errors, settings and
firmware versions is a way to save diagnostic information, which
Blendtec
's customer service and repair experts will use if
®
problems arise with the blender. To export blender statistics to a
USB drive, complete the following steps:
1. Locate the USB port on the bottom of metal motor housing on
the blender.
2. Plug the USB drive into the blender's USB port.
Note: If the blender is in manual or automatic operation mode,
the USB drive menu will automatically load on the screen. If
to easily
the blender is in programming mode, go to the main menu
TM
and select USB Drive.
3. Press
again to confirm export of counts to the ICBUCNTS.CSV file or
press
4. After the export process is finished, remove the USB drive
from the blender
Exporting and transferring profiles
to select.
For more information on exporting and transferring information
and BlendWizard
• For all Connoisseur
bottom of the metal motor housing. Connoisseur
counter models will need the plastic plate removed to access the
USB port.
3.3 EZ 600™ AND CHEF 600™
600 SERIES: ES3 Chef 600, ES3 EZ 600
3.3.1 ABOVE COUNTER INSTALLATION
to scroll to Export Counts. Press
to cancel and return to the previous menu.
please see my.blendtec.com
TM
models, the USB port is located on the
TM
to select. Press
825 above
TM
11