Télécharger Imprimer la page

Blendtec COMMERCIAL Serie Manuel D'utilisation page 7

Masquer les pouces Voir aussi pour COMMERCIAL Serie:

Publicité

SECTION 3
INSTALLATION & OPERATIONAL OVERVIEW
3.1 STEALTH® MODELS
STEALTH SERIES: CQB1 Stealth 885, IQB1 Stealth 885 (in counter
version), CQB2 Stealth Nitro, CQB3 Stealth X, CQB3 Stealth Nitro X
3.1.1 ABOVE-COUNTER INSTALLATION
FIGURE 1
Allow a clearance of at least 5.5" (14 cm) from the sound
enclosure to the wall and 26" (66 cm) from the countertop to
any over-the counter cabinetry.
Be sure the blender is installed as per the drawing in Figure
1. Ensure the blender has 7.5" (19 cm) of unobstructed
space surrounding the sides and back of the blender to
prevent overheating.
Select a location that is near an electrical outlet. Also consider
proximity to ingredients and patrons as well as available
counter space.
Ensure there is enough room above and around the unit to
allow for unhampered movement of the sound enclosure.
3.1.2 IN-COUNTER INSTALLATION
Ensure the blender is installed per the drawing in Figure 2.
Ensure electrical supply is accessible under the countertop.
The countertop can be no thicker than ¾" (1.9 cm) for
adequate ventilation.
Allow a clearance of at least 5.5" (14 cm) from the sound
enclosure to the wall and 22" (56 cm) from the
countertop to any over-the counter cabinetry.
Ensure lower cabinetry allows adequate airflow.
There should be at least 3" (7.6 cm) of unobstructed space
below and around the motor. Cabinetry should not be closed;
it should allow air to flow freely from the outside to the inside
of the cabinet space.
If installing more than one blender, allow 16" (40.6 cm) of
center-to-center blender spacing.
Cut a hole in the countertop 4 ⅜" (11.1 cm) wide and 5 ⅞" (14.9
cm) long (see the countertop hole template in Appendix A).
Ensure that the 4 ⅜" (11.1 cm) sides are parallel to the front
edge of the counter.
Note: Double check to ensure that all space requirements and
measurements are correct BEFORE cutting.
Place blender into the countertop; ensure the gasket is flat
against the counter surface.
FIGURE 2